Summary of Contents for AMT 168-B

  • Page 1 Installation Manual AMT 168-B Brushless Motor Boom Barrier Version:1.1 Date: Oct, 2022...
  • Page 2: Table Of Contents

    www.amts.pk Menu 1. Product introduction ........... 1 2. External device considerations ......1 3. Installation and commissioning instructions ..2 4. Main board wiring diagram ......... 2 5. Setup operation ..........3 6. Parameter list set up .......... 5 7. Main board debugging ........6...
  • Page 3: Product Introduction

    www.amts.pk 1. Product introduction This product is a DC brushless motor boom barrier: ① Product power supply is used for 24V DC power supply, eliminating the traditional 220V AC power supply, and the risk factor is reduced during the installation process to meet the safety production requirements;...
  • Page 4: Installation And Commissioning Instructions

    www.amts.pk 3. Installation and commissioning instructions ① the line is buried According to the customer's request, the position of the chassis is fixed. If the concrete foundation needs to be poured, it can be completed in advance (the size of the base is about 100-150mm larger than the size of the bottom of the gate), and the center of the fixed position of the chassis can be controlled to the control room or Pre-buried or excavated cable trenches between the booths, buried the conduits, and penetrated the 3X1.5 square millimeter power cord and the 4X0.5 square millimeter control cable used in the equipment.
  • Page 5: Setup Operation

    www.amts.pk Precautions: A. Motor movement interface: There are 8 lines from the movement, and the three thick lines are connected to the motor movement interface. The wiring is as follows. (Note: The following is the wiring method used by our company. The motor used by our company is a city-state brushless motor. The colors of the three thick lines are blue, green and yellow respectively.
  • Page 6 www.amts.pk Step 2: After setting the parameters, press the reset button to restart the motherboard. If the self-test is correct, you can modify the parameters later without restarting the motherboard. Observe whether the gate is self- tested, that is, the gate will automatically drop when the power is turned on, and the parameter display will decrease.
  • Page 7: Parameter List Set Up

    www.amts.pk 6. Parameter list set up DC Boom Barrier Parameter Setup Form Menu Setup Default Parameter description number range value Boom barrier speed adjustment, bigger value 0-90 means moving faster Boom barrier speed adjustment, bigger value 0-90 means moving faster 0-90 In-position speed adjustment 0-255...
  • Page 8: Main Board Debugging

    www.amts.pk 0-255 Controller signal receive matching function Open barrier distance deceleration 0-255 (for high speed boom barrier only) Close barrier distance deceleration 0-255 (for high speed boom barrier only) Note: All parameters above are for reference only, they should be based on actual operating parameters on site.
  • Page 9 www.amts.pk when the switch is turned on/off. If the parameter is too large, the on/off lever will be shaken. D: Resisting rebound adjustment 1: L-4 adjusts the resistance of the rebound 2: L-C adjusts the resistance to rebound If the parameter is too small, the gate will be returned to the half when it is turned on/off, and the parameters will be adjusted according to the site conditions.