Chapter 3 Management - Vt-100; The Cim Management Screen; Figure 3. Cim Management Screen; Table 2. Cim Management Status Definitions - Canoga Perkins EdgeAccess UCS 1202 CIM User Manual

Chassis interconnect module
Table of Contents

Advertisement

Chapter 3
Management - VT-100
To connect to and manage the CIM, use either the serial or Ethernet port on an optional DMM
and an application such as HyperTerminal. For details about accessing the DMM and using the
management software, see the User Manual for the 1500 or 1502 Domain Management Module
for your system.
3.1

The CIM Management Screen

If the domain includes an optional DMM, you can access the CIM Management screen to view
the current status of the chassis. The CIM Management screen reports status and alarm
conditions that help verify the cause, source, and current condition of an alarm. Figure 3 shows
the CIM Management screen and Table 2 describes the fields.
CIM MANAGEMENT
Chassis Type:
Redundant Power:
Primary Power Type:
Primary Power Status:
Secondary Power Type:
Secondary Power Status: Good
Fan Installed:
Fan Status:
Up Link Installed:
Down Link Installed:
CIM Model:
CIM Firmware:
CIM Serial Number:
CIM Hardware Version:

Figure 3. CIM Management Screen

Table 2. CIM Management Status Definitions

Field
CIM Status
CIM clock
CIM Providing Clock
CIM Interlink Clock
Alarm Relay Status
Alarm Latch Status
EdgeAccess Universal Chassis System
CIM : 2
2U Chassis
Yes
DC isolated
Good
DC isolated
Yes
Good
No
No
1202-2000
3.5
20011195838
A2A
1. Reset Major and Minor Alarm Relay
Shows if this CIM is online or offline
Lists status for the clock signal on this CIM; either good or failed
Enabled shows that this CIM provides the clock signal or Disabled
shows that another CIM provides the clock signal
Lists status for the clock signal on the link; either good or failed
Shows an alarm condition, Major or Minor, in this chassis or a linked
chassis
Shows a latched alarm relay, Major or Minor, in this chassis
Model 1202 CIM User Manual
CIM Status
CIM clock:
CIM Providing Clock:
CIM Interlink Clock:
Alarm Relay Status:
Alarm Latch Status:
Backplane Alarm Inputs: Off
CIM Major Alarm:
CIM Minor Alarm:
Chassis Temperature:
Definition
Online
Good
Enabled
N/A
Major
Major
Off
Off
OK
3-1