Page 1
Operating instructions Ion Basic charging station Ion Key charging station Ion Basic Protect charging station Ion Key Protect charging station...
About these instructions About these instructions Target group These instructions describe how you can charge your electric vehicle using the Ion charging station from OBO. The instructions are intended for the operators of the Ion charging stations Basic, Key, Basic Protect and Key Protect.
Danger of electrical voltage! Ensure de-energisation before working on the device. Electrical technician! Only electrical technicians may mount and connect the device. Protection class! The device corresponds to Protection Class 1 according to DIN EN 61140 (VDE 0140-1). 6 | EN OBO Bettermann...
Product overview Product overview The Ion charging station series comprises 4 different models. The charg- ing station possesses different features, depending on the model. Ion Basic Ion Basic Ion Key Ion Key Protect Component/charging station Protect charging station charging station...
Product overview Ion Basic Ion Basic Ion Key Ion Key Protect Component/charging station Protect charging station charging station charging station charging station Potential-free enabling contact (e.g. for PV systems, ripple controller) Modbus RTU interface ...
Do not touch the contact pins of the charging cable. Note! If the temperature of the charging station rises above 60 °C, the charg- ing operation is interrupted automatically until the charging station has cooled down to 40 °C. Ion Basic charging station Ion Basic Protect charging station Ion Key charging station Ion Key Protect charging station Fig 1: Switching on the charging station Operating instructions, Ion charging station 9 | EN...
Page 10
Damage to the charging station! The vehicle may not be moved during the charging operation. 5. Start the charging operation on the vehicle. → Status LED is continuously green and there is a clicking noise. 10 | EN OBO Bettermann...
Page 11
Charging an electric vehicle Alternatively Fig 3: Ending the charging operation Note! The vehicle ends the charging operation automatically. Status LED is continuously blue again. 6. Release the charging connector from the vehicle and reattach the protective cap. 7. Wind the charging cable on the cable bracket without kinks Optional 8. Switch off the charging station using the on/off switch, in order to avoid current consumption in standby mode.
SPD LED is red Charging station continues to tion engineer. function but without surge protec- tion. Switch off the charging station, switch off the fuse in the building installation. Contact Unknown error – the electrical technician/installation engineer. 12 | EN OBO Bettermann...
Electrical techni- Annually or when the system is changed VDE 0105-100 cian *With the Ion Basic Protect and Ion Key Protect charging station variants, the surge protection installed in the charging station must be disconnected before the inspection. Checking the function...
What could be the reason? → Check whether a limitation of the charging power was set in the ve- hicle (refer to the operating instructions of the vehicle to be charged). Technical data Ion Basic Ion Key Ion Basic Ion Key...
Need help?
Do you have a question about the Ion Basic and is the answer not in the manual?
Questions and answers