Thank you for purchasing WI-922 stationary oral irrigator manufactured by B.Well. The device provides for effective cleaning of interdental space and for plaque removal. It's use averts formation of dental scale and is an excellent prevention of caries and periodontal diseases.
WI-922 oral irrigator is an essential oral care instrument for dental bridges, implants, crowns, and braces. It also may be used for gum massage that improves blood circulation, and thus promotes sanitation.
ATTENTION!
When using electrical products, especially in presence of children, safety measures shall be taken.
The device is not intended for independent use by children or by persons with limited physical or mental abilities or with insufficient experience and knowledge, unless they are trained and instructed on device use by persons responsible for their safety.
BEFORE USING THIS DEVICE PLEASE READ CAREFULLY THE INSTRUCTIONS FOR USE
To reduce risk of electric shock, burns, combustion or injury:
BEFORE USING THIS DEVICE PLEASE CAREFULLY READ THE FOLLOWING INFORMATION!
It is forbidden to use the following solutions as solutions for oral irrigation:
The following liquids may be used for oral irrigation:
B.Well WI-922 oral irrigator is designed for:
Application range covers individual and family use. The operating principle of the stationary irrigators consists in targeted exposure of the surface of teeth, gums, mouth mucous and orthodontic systems to adjustable water flow.
The irrigator removes food debris and malignant bacteria with water jet.
Contraindications: Prior to use of the irrigator, it is recommended to consult the dentist in case of surgical interventions in the oral cavity and in case of acute exacerbation of a chronic disease of the oral cavity. You may experience insignificant gum bleeding during several first uses of the irrigator. If your gums are healthy, any bleeding shall disappear within 1-2 weeks of use. If you experience gum bleeding after 2 weeks of use, stop using the irrigator and consult the dentist.
SET:
Standard nozzle (3 pcs.)
It is designed for comprehensive care for oral cavity, i.e. for cleaning of interdental spaces and gum massage
Tongue cleaning nozzle (1 pcs.)
It is designed for gunk removal and for making your breath fresh
Periodontal nozzle (1 pcs.)
It is designed for cleaning of gum margin and of gingival pockets, as well as for cleaning of denture surface under prosthesis and dental bridges
Orthodontic nozzle (1 pcs.)
It is designed for cleaning of the gaps between densely spaced teeth and gum margin. It also ensures the hygiene of braces and other orthodontic systems
Nozzle for implants, dental bridges, crowns, and veneers (1 pcs.)
It is designed for delicate surface cleaning of implants, dental bridges, crowns and veneers
Connect the device to the mains. Insert the plug in the outlet. If the plug is equipped with a switch, make sure it is turned on.
Remove the water tank from the main unit by strongly holding the device with one hand.
Pull the tank upwards holding the cover.
Thereafter, remove the cover from the tank and fill the tank with warm water.
Place the tank back in the main unit, press it down by applying slight uniform effort and place the cover back.
Insert the nozzle in the opening on the surface of the irrigator handle.
Colored ring on the nozzle shall become tightly close to the handle. To remove the nozzle, press the nozzle removal/fixation button, and remove the nozzle.
When the jet intensity control is in the extreme left position, the device is off. Turn the control clockwise until a "click" sound is heard. The initial pressure level is minimal. Smoothly turn the control clockwise to increase the jet intensity.
Prior to using the device, the jet intensity control should be placed in the extreme left position. Water supply button shall be in OFF position.
Place the nozzle into your mouth. Turn on the device with your free hand as described in Figure below.
Place the water supply button in ON position.
Select the jet intensity.
Jet direction may be changed by turning the nozzle rotation angle control in the upper part of the handle in any direction.
Nozzle rotation angle is 360˚.
Direct the jet at 90° to the gum line. Appose your lips to avoid splashes. But do not close your mouth, let the water freely flow out of your mouth.
For better results start with side and distant teeth and move towards the front teeth.
Move the nozzle along the gum line from one tooth to another, slowing down between the teeth. Keep cleaning till the areas around and between the teeth are clean.
You may stop water supply at any time by moving down the button on the slide switch on the handle into OFF position.
The device shall automatically turn off, if the procedure lasts for over 3 minutes.
Note.
Once the procedure is over, turn the device off and put the irrigator handle in the holder, remove the remaining water from the tank. Disconnect the device from the mains.
The device shall always be stored out of reach of children.
Utilize the devices as per the applicable standards; do not dispose with household wastes.
After use of the device, disconnect it and wipe it dry. Prior to cleaning the device, make sure the power cord is disconnected from the outlet. Do not use coarse cloths, brushes and abrasive agents for device cleaning. Wipe the device and the irrigator handle with the hose with dry soft cloth.
Wash the nozzles with water after each use. It is recommended to disinfect the nozzles by placing them for 5-10 minutes in any of the following solutions: alcohol solvent, 3% hydrogen peroxide solution, 1% chlorhexidine solution. It is recommended to rinse the nozzles with warm water after disinfection in the solution. Contactless cleaning and disinfection are allowed, including cleaning and disinfection in ultrasonic and ultraviolet cleanser.
If the irrigator is used with any solution, it shall always be rinsed after each use. For the above purpose fill the water tank with warm water and turn the device on, direct the irrigator handle downwards into the sink, and wipe the device dry.
A number of possible problems and issues that may appear at operation of the device may be solved by the user (see the table below).
If none of the suggested solutions resolves the problem, stop using the device and contact the service center.
Problem | Cause | Solution |
The irrigator does not work | The device is not connected to the mains | Check connection to the mains |
No voltage in the outlet | Wait for power restoration | |
Poor contact between the plug and the electrical outlet | Connect the device to a different outlet and call for the specialist for repair | |
Low pressure or no water flow from the nozzle | Wrong position of the jet intensity control | Adjust the pressure using the jet intensity control |
Incorrect placement of the water tank, the connection is not tight | Place correctly the water tank in the main unit | |
There is no water in the water tank | Fill in the water tank | |
The nozzle is plugged up | Replace the nozzle with a new one | |
Wear of pump parts | Contact the service center | |
The hose is damaged | Check the hose for integrity Otherwise contact the service center | |
Water leakage from the nozzle | The nozzle is inserted incorrectly or is not inserted fully | Insert the nozzle until the click of the fixation mechanism spring of the nozzle |
The nozzle is plugged up or the nozzle base is worn out | Replace the nozzle with a new one | |
Wear of the nozzle fixation mechanism with nozzle rotation angle control | Contact the service center |
Power | Power supply by single-phase alternating current mains, 50-60 Hz, 100-240 V. |
Wattage | 18 W |
Water pressure, kPa | 207-827 |
Water jet pulsation frequency, pulse/min | Min 1250 pulse/min Мах 1850 pulse/min |
Usage time of the full capacity of the water tank | МАХ 155 s |
Maximum time of uninterrupted use | 30 min |
Tank capacity | 600 ml |
Number of nozzles in a set | 7 |
Pressure adjustment | Smooth, uninterrupted, ten-phase |
Storage condition | Temperature: from -40 ˚С to +55 ˚С; Humidity: ≤ 90%; Atmospheric pressure: 70 kPa – 106 kPa |
Operation conditions | Temperature: from +5 ˚С to +40 ˚С; Humidity: ≤ 90%; Atmospheric pressure: 70 kPa – 106 kPa |
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.