THORLABS GPS011-EC Original Instructions Manual
THORLABS GPS011-EC Original Instructions Manual

THORLABS GPS011-EC Original Instructions Manual

Galvo scanner system linear power supply
Hide thumbs Also See for GPS011-EC:

Advertisement

Quick Links

GPS011-EC
GPS011-US
GPS011-JP
Galvo Scanner System
Linear Power Supply
Original Instructions
HA0213T

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GPS011-EC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for THORLABS GPS011-EC

  • Page 1 GPS011-EC GPS011-US GPS011-JP Galvo Scanner System Linear Power Supply Original Instructions HA0213T...
  • Page 2: Table Of Contents

    Chaper 4 Regulatory ....................7 4.1 Declarations Of Conformity .............. 7 4.1.1 For Customers in Europe ................ 7 4.1.2 For Customers In The USA ..............7 4.2 CE Certificate ..................8 Chaper 5 Thorlabs Worldwide Contacts ..............9 Page 0 ETN049037-D02...
  • Page 3: Introduction

    Chapter 1 Overview Chapter 1 Overview 1.1 Introduction The GPS011 power supplies are low noise, linear supplies designed to minimize electrical interference for maximum system resolution when using our Galvo Scanning Systems. The supplies allow two driver cards to be powered via the separate 2 m power cables supplied with the galvo units.
  • Page 4: Safety Information

    Galvo Scanner System Linear Power Supply Chapter 2 Safety 2.1 Safety Information For the continuing safety of the operators of this equipment, and the protection of the equipment itself, the operator should take note of the Warnings, Cautions and Notes throughout this handbook and, where visible, on the product itself.
  • Page 5: Environmental Conditions

    Chapter 3 Installation and Operation Chapter 3 Installation and Operation 3.1 Environmental Conditions Warning Operation outside the following environmental limits may adversely affect operator safety. Location Indoor use only Maximum altitude 2000 m Temperature range C to 40 Maximum Humidity Less than 80% RH (non-condensing) at 31°C To ensure reliable operation the unit should not be exposed to corrosive agents or excessive moisture, heat or dust.
  • Page 6 Galvo Scanner System Linear Power Supply 2) Screw the outer casing of the plug clockwise until the connector is fully fastened. OUTPUT ±15V DC 3.0A/0.1A, 1.4/6.3 msec OUTPUT ±15V DC 3.0A/0.1A, 1.4/6.3 msec Fig. 3.1 Connecting the Power Cable to the PSU 3) Push the 3-way crimp housing on the other end of the cable into the driver card connector J10.
  • Page 7: Connecting The Ac Power

    Chapter 3 Installation and Operation 3.3 Connecting the AC Power The unit must be connected only to an earthed (grounded) mains power outlet. Note The unit is supplied with the input voltage and fuses configured to be compatible in the region to which it was shipped. No further adjustment should be necessary. 1) Connect the power cord to the socket on the rear panel of the unit - see Fig.
  • Page 8: Using The Power Supply Unit

    Galvo Scanner System Linear Power Supply Fig. 3.4 Rear Panel -JP Models 3.4 Using the Power Supply Unit 1) Make connections and voltage selection settings as detailed in Section 3.2. and Section 3.3. 2) Move the Power switch on the rear panel to the ‘—’ position. 3) To disconnect the power, move the switch to the ‘0’...
  • Page 9: Specifications

    Chapter 4 Specifications Chapter 4 Specifications Parameter Value Input Voltage Range Switchable as follows: 100V AC 50 or 60 Hz 115V AC 60 Hz 230 V AC 50 Hz Output Voltage ±15 V DC 3.0A/0.1A, 1.4/6.3 msec (maximum duty cycle) Fuse Type Input Voltage Dependent: 100 V: T2.5 A Anti-Surge Ceramic...
  • Page 10: Declarations Of Conformity

    Galvo Scanner System Linear Power Supply Chapter 5 Regulatory 5.1 Declarations Of Conformity 5.1.1 For Customers in Europe See Section 5.2. 5.1.2 For Customers In The USA This equipment has been tested and found to comply with the limits for a Class A digital device, persuant to part 15 of the FCC rules.
  • Page 11: Ce Certificate

    Chapter 5 Regulatory 5.2 CE Certificate Page 9 Rev E Jan 2022...
  • Page 12 "End of life" units must be returned to Thorlabs or handed to a company specializing in waste recovery. Do not dispose of the unit in a litter bin or at a public waste disposal site.
  • Page 13 www.thorlabs.com...

This manual is also suitable for:

Gps011-usGps011-jp

Table of Contents