  • Page 1 Amplifiers USB-Sensor-Interface LCV-USB3 Lorenz Messtechnik GmbH Obere Schlossstrasse 127/129/131 090374a_LCV-USB3 73553 Alfdorf Phone +49 7172 93730-0, Fax +49 7172 93730-22 Technical changes, errors and misprints excepted. 1/13 info@lorenz-messtechnik.de, www.lorenz-messtechnik.de...
  • Page 2: Table Of Contents

    Pin Assignment for Active Sensors with ±5V or ±10V Signal Pin Assignment for Active Current Sensors with mA Signal Option Digital Input at Channel B Pin Assignment for Auxiliary Supply and Digital Input Application Example Displacement Sensor Potentiometric (supplied by LCV-USB3) Debugging Technical Data Options Calibrations mV/V...
  • Page 3: Imprint / Copyright

    These operating instructions do not constitute an agreed quality agreement or durability guarantee within the meaning of § 443 BGB (German Civil Code). Technical changes, errors and misprints excepted. No part of this publication may be reprinted without the written permission of Lorenz Messtechnik GmbH, Alfdorf. Important Notes / Keeping Before installing and commissioning the device, these operating instructions, and in particular the corresponding safety instructions, must be read.
  • Page 4 The devices do not contain any parts that require or can be serviced by the user. Repairs may only be carried out by Lorenz Messtechnik GmbH. If it can be assumed that safe operation of the device is no longer possible, it must be put out of operation immediately and secured against unintentional operation.
  • Page 5: Intended Use

    Intended Use Devices from Lorenz Messtechnik GmbH are to be used exclusively for measuring tasks and the di- rectly associated control tasks. Any use beyond this is considered to be improper. The valid legal and safety regulations must be observed during measurement. The instrument is not a safety component in the sense of its intended use and it is transported and stored properly.
  • Page 6: Health Protection And Safety

    Conversions and Changes The device may not be modified in terms of design or safety without the express consent of Lorenz Messtechnik GmbH. Any modification excludes any liability on our part for damages resulting there- from. Repairs and modifications are prohibited. CE Marking With the CE marking, Lorenz Messtechnik GmbH guarantees that its product meets the requirements of the relevant EC directives. Preamble Product Description The LCV-USB3 is a measurement amplifier for the conversion of analog signals into digital measured values. These measured data can be requested through the Computer via the USB-interface.
  • Page 7: Safe And Correct Use

    If the LCV-USB3 is calibrated together with the sensor, you can take the output values from the test certificate. If the LCV-USB3 is calibrated without a sensor, you can take the output values as described above. In this case, they are pre-calibrated with a high precision source.
  • Page 8: Pin Assignment For Strain Gauge Sensors With Mv/V Signal

    Control signal Grey If available in sensor Shield Shielding Connect shield with sensor housing Lorenz Messtechnik GmbH Obere Schlossstrasse 127/129/131 090374a_LCV-USB3 73553 Alfdorf Phone +49 7172 93730-0, Fax +49 7172 93730-22 Technical changes, errors and misprints excepted. 8/13 info@lorenz-messtechnik.de, www.lorenz-messtechnik.de...
  • Page 9: Option Digital Input At Channel B

    Pin Assignment for Auxiliary Supply and Digital Input Description Auxiliary supply: Auxiliary supply: Control voltage: Control voltage: Lorenz Messtechnik GmbH Obere Schlossstrasse 127/129/131 090374a_LCV-USB3 73553 Alfdorf Phone +49 7172 93730-0, Fax +49 7172 93730-22 Technical changes, errors and misprints excepted. 9/13 info@lorenz-messtechnik.de,...
  • Page 10: Application Example

    Application Example Displacement Sensor Potentiometric (supplied by LCV-USB3) - With “active sensors” only (type: U5) - Accuracy is depending on the quality of the reference voltage 5V reference voltage controller Signal+ Signal+ 0V / GND 0V / GND Output 0 … 20000 digits Output 0 …...
  • Page 11: Debugging

    Install driver package LCV-USB3 is not possible stalled • The first start-up LCV-USB3 must be carried out with administrator rights Supply voltage is over- • Check whether the connected strained in such a way that it sensor corresponds to the speci-...
  • Page 12: Technical Data

    Digital input at channel B LCV-USB3/TR-EXT 113591 Input range ±4.5 mV/V per channel LCV-USB3/SI-USB/- RS485/-ETH/SI-USB3/4.5 mV/V 114104 Sensor exc. LPM 4V max. 20 mA, input range LPM 5V LCV-USB3/LPM 115125 Adjustment linear potentiometer LCV-USB3/SI-USB/SI-USB3/LPM Lorenz Messtechnik GmbH Obere Schlossstrasse 127/129/131 090374a_LCV-USB3 73553 Alfdorf Phone +49 7172 93730-0, Fax +49 7172 93730-22 Technical changes, errors and misprints excepted.
  • Page 13: Calibrations Mv/V

    Document number 090235, “Driver Installation Description Sensor-Interfaces SI-USB3, LCV-USB3, LCV-USB2, LCV-USB, SI-USB and Sensors with USB Interface (USB Driver.exe)“ (German 090198) • Document number 090110 Lorenz protocol “A flexible command set for digital sensors and interfaces“ Lorenz Messtechnik GmbH Obere Schlossstrasse 127/129/131 090374a_LCV-USB3 73553 Alfdorf Phone +49 7172 93730-0, Fax +49 7172 93730-22 Technical changes, errors and misprints excepted.