Pin Assignment for Active Sensors with ±5 V or ±10 V Signal ..........7 Pin Assignment for Active Current Sensors with 0 .. +20 mA Signal ........7 Application Example ........................8 Displacement Sensor Potentiometric (supplied by SI-USB3) ..........8 Debugging ............................9 Specifications ..........................10 Continuative Documents ......................
Technical changes reserved. All trademarks or brands used in this document refer only to the respective product or the holder of the trademark or brand. Lorenz Messtechnik GmbH does not raise claims to other than its own trademarks or brands. E-Mail: info@lorenz-sensors.com...
Lorenz Messtechnik GmbH technology devices. For this purpose it is absolutely necessary that all measures are carried out by qualified personnel. All persons concerned with the project planning, installation and service of Lorenz Messtechnik GmbH devices, must be familiar to the security concepts in automatic control and should be qualified in this sense.
If parts of the device are loose or slack If the connection cables show visible damages Furthermore, we point out that all obligations of Lorenz Messtechnik GmbH exclusively result from the respective sales contract in which the guarantee has been conclusively settled.
The Lorenz USB drivers are required for the operation on a PC. They are available for download on our website. Guidance is available in document no. 090235. For the operation of the SI-USB3 we recommend the software VS3. It is available for download on our website. Guidance is available in document no 090367.
Obere Schloßstr.131 LORENZ MESSTECHNIK GmbH +49 7172/93730-0 D-73553 Alfdorf Fax +49 7172/93730-22 Pin Assignment SI-USB3 SUBD Function Type (Female) 15-pole Ground (supply) 4 V and 12 V SI-USB3 Supply for active sensors 12 V n.c. reserved reserved Ground (supply) 4 V and 12 V n.c.
LORENZ MESSTECHNIK GmbH +49 7172/93730-0 D-73553 Alfdorf Fax +49 7172/93730-22 Application Example Displacement Sensor Potentiometric (supplied by SI-USB3) With “active sensors”, only (type: U5). Accuracy is depending on the quality of the reference voltage. 5 V Reference ≤ 200mA R >...
Debugging Connection to the SI-USB3 is Driver not or incorrectly installed. Install driver package. not possible. The first start-up of the SI-USB3 must be carried out with administrator rights. Supply voltage is overstrained in Check whether the connected such a way that it breaks down.
+49 7172/93730-0 D-73553 Alfdorf Fax +49 7172/93730-22 Continuative Documents Following documents contain reference information about the SI-USB3 / LCV-USB2: Document number 090232, “Operation Manual for Sensor Interface LCV-USB2” (German 090205). Document number 080727, data sheet “Sensor-Interface with USB” (German 080726).