Page 1
M500-605-100-M01 Rev 1.00 WORK INSTRUCTION Sealing Methods – C510, C520 and C527 Sealing with calibration seal stickers Equipment required. • Destructible stickers • Setup switch cover • Load cell connection cover (M5010) Method 1. Place the setup switch cover in position so that it covers the setup switch and 2 closure screws.
Page 2
M500-605-100-M01 Rev 1.00 WORK INSTRUCTION Figure 1: Setup Switch and pluggable screw terminal load cell connection sealing with a sticker. 3. Either • Place the load cell connector adaptor cover over the load cell connector adaptor and place a sticker across the load cell connector adaptor cover as shown in Figure 1.
Page 3
M500-605-100-M01 Rev 1.00 WORK INSTRUCTION Figure 2: Sealing DB9 loadcell connection. Sealing with wire and Lead seals The Setup switch cover and pluggable screw terminal load cell connection can also be secured with wire and Lead seals if required. This will also seal access to two of the enclosure closure screws.
Page 4
M500-605-100-M01 Rev 1.00 WORK INSTRUCTION Figure 3: Wire seal loop locations Page 4 M500-605-100-M01...