The Prince Castle DHB-BK Bins and Retro Bun Timer and New Bun
Cabinet Timers can be inter-connected to form the CastleNet
Communication Network. The network can be used for data transfer
between bins and timers for menu updates or to transfer product hold
time from bin-to-bin.
Each bin is supplied with a standard 25' cable and allows units to be
"daisy-chained" together to form the network. If cable is too short, use
Prince Castle Extender Cable Kit, P/N PC-COMEXT.
The factory default address for Main bins and timers is address 1.
The factory default address for Specialty bins and timers is address 2.
If a third bin is used, the address must be set at 3.
The factory default address for the Retro Bun Timer is bunF.
IMPORTANT: Each timer must have a different address.
2
If a location has three bins, it is recommended that the bins
and timers be set consecutively to addresses 1 through 3.
Bin 1
TRANSFER
MENU
BKFT
ENTER
REG
Example
Use the UP or DOWN Arrow buttons to scroll to the desired
4
address. Press the PRINCE CASTLE LOGO Button to store the
new address.
Available addresses are:
bin1 thru bin 9, binA, binB, binC, binD, binE
and binF.
IMPORTANT: Continue to step 5 to
check the timer address. No two
timers can have the same address.
To change the timer address, turn the unit power switch off and
6
wait 15 seconds. Turn the power switch back on and immedi-
ately press and hold the PRINCE CASTLE LOGO button and the
DOWN Arrow button for approximately 6 seconds or until the
display shows SET ADDR ⇑ ⇓ BIN2.
The address number will blink on/off.
SET
Printed in USA 8/06 © 2006
CastleNet® Communications Network
®
Bin 3
Bin 2
TRANSFER
MENU
TRANSFER
BKFT
ENTER
REG
UPPER
PROG
bar3
LOWER
ACTUAL
TEMP
SET-
POINT
TRANSFER
ADDR
Telephone jack plugs are located on the back of the unit.
1
Connect the units using the cables provided as shown here.
BIN 1
EXTERNAL
IN
A. Turn the power switch off, wait 15 seconds. Turn the switch
3
to ON while pressing and holding the ACTUAL and SET-
POINT buttons. The display will show the current bin
address.
B. Continue to hold the buttons until PROG LED turns on.
UPPER
PROG
bar2
LOWER
MENU
BKFT
ENTER
REG
ACTUAL
TEMP
SET-
POINT
To check the timer address, press and hold the PRINCE
5
CASTLE LOGO button and the DOWN Arrow button.
The current timer address will be displayed in the far right timer
display.
To change the timer address, proceed to step 6.
Use the UP or DOWN Arrow button to scroll to the desired
7
address. Press the MENU/ENTER button to store the new
address and return to normal operating mode.
Available addresses are:
bin1 thru bin 9, binA, binB, binC, binD, binE and binF.
ET
ADDR
10
Product Holding Bin
DHB2PT-27 Series
BIN 2
BIN 3
RETRO
BUN
TIMER
EXTERNAL
EXTERNAL
IN
IN
OUT
OUT
Example
UPPER
PROG
LOWER
ACTUAL
POINT
TRANSFER
EGGS
EGGS
TRANSFER
OUT
prog
TEMP
SET-
541-536revB