FPI-Hand User Manual
Product name: FPI-Hand
Total: 22
FPI-Hand User Manual
The user manual is suitable for the following model:
Model
Product Type
FPI-Hand
Xiamen Four-Faith Smart Power Technology Co.,Ltd.
Hotline :400-8838 -199
Tel:+86-592-6300320
Fax:+86-592-5912735
Web:https://en.four-faith.net/
Add:11th Floor, A-06 Area, No.370, Chengyi Street,
Jimei, Xiamen, Fujian, China.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FPI-Hand and is the answer not in the manual?

Questions and answers

Summary of Contents for Four-Faith FPI-Hand

  • Page 1 Total: 22 FPI-Hand User Manual The user manual is suitable for the following model: Model Product Type FPI-Hand Xiamen Four-Faith Smart Power Technology Co.,Ltd. Hotline :400-8838 -199 Tel:+86-592-6300320 Fax:+86-592-5912735 Web:https://en.four-faith.net/ Add:11th Floor, A-06 Area, No.370, Chengyi Street, Jimei, Xiamen, Fujian, China.
  • Page 2 FPI-Hand Power Meter User Manual Files Revised Record Date Version Remark Author V1.0.0 Hu Jiangxia Initial version 2020-04-30 V1.0.0 1. Contents translation and layout 2020-05-14 2. Pictures replacement and format modification Add:Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen.China W eb:https://en.four-faith.net/...
  • Page 3 All contents in the files are protected by copyright law, and all copyrights are reserved by Xiamen Four-Faith Communication Technology Co., Ltd. Without written permission, all commercial use of the files from Four-Faith are forbidden, such as copy, distribute, reproduce the files, etc., but non-commercial purpose, downloaded or printed by individual (all files shall be not revised, and the copyright and other proprietorship notice shall be reserved) are welcome.
  • Page 4 FPI-Hand Power Meter User Manual Appearance Add:Floor 11, Area A06, No 370, chengyi street, Jimei, Xiamen.China W eb:https://en.four-faith.net/ Hotline:400-8838-199 Tel:0592-6300320 Fax:0592-5912735...
  • Page 5: Table Of Contents

    FPI-Hand Power Meter User Manual Content Chapter1 Introduction of Product....................6 1.1 General..........................6 1.2 Application topology...................... 6 1.3 Product Features......................6 Chapter2 Technical specification....................8 2.1 Working environment....................8 2.2 Hardware system......................8 2.3 Physical Characteristics....................8 Chapter3 Function description....................9 3.1 Keyboard........................9 3.2 Power on........................
  • Page 6: Chapter1 Introduction Of Product

    Chapter1 Introduction of Product 1.1 General FPI-Hand is portable operating equipment which is for remote management of the front-end products. It suitable for all the overhead line fault indicators in our company. It can not only read the operating status, battery voltage, load current, electric field and other information of the fault indicator, but als o manage the fault indicator.
  • Page 7 FPI-Hand Power Meter User Manual Support both Chinese and English languages  Data transfer and receive indicator light which displays status information  Support reading indicator operation parameters and setting parameters  Support a variety of types of indicators ...
  • Page 8: Chapter2 Technical Specification

    FPI-Hand Power Meter User Manual Chapter2 Technical specification 2.1 Working environment Item Content Working temperature:-20℃~70℃ Temperatu Storage temperature:-40℃~70℃ relative 5~95% (Unfreezing) humidity Altitude ≤2000m 2.2 Hardware system Item Content Industrial-grade ultra-low power MCU FLASH 512MB SRAM 64KB wireless 433MHz communication 2.3 Physical Characteristics...
  • Page 9: Chapter3 Function Description

    FPI-Hand Power Meter User Manual Chapter3 Function description 3.1 Keyboard Layout of keys is as follows: ON : Long press for 3 seconds to turn on the machine when it is off .  OFF : Press [OFF] to turn off the machine.
  • Page 10: Communicate With Fault Indicators

    FPI-Hand Power Meter User Manual turn on again, without any operation, the device will automatically shut down after 3 minutes; 3.3 Communicate with fault indicators Press the [UP] or [DOWN] button to select the language, then press [OK] to enter “Search parameters ”...
  • Page 11 Press [Return] to back to searching page, showing as below: In this page, users can search indicators, write or set parameters, and battery voltage and version of FPI-HAND can be viewed. Press [Back] to back to main menu, press[Back] again to back searching page.
  • Page 12: Menu Description

    FPI-Hand Power Meter User Manual [Page] to move the cursor to corresponding indicator, press [OK] (it indicates that all subsequent operation are for this indicator), then back to main menu. Please pay attention that indicators have activation time, it means If the inactive time after searching exceeds the active time, the indicator will enter sleeping mode, and it will no longer respond to any reading, writing, modification or operation of the indicator.
  • Page 13: Real-Time Data

    FPI-Hand Power Meter User Manual indicators, such as operation parameters, current etc. Ctrl Operation (Remote control for indicators): Such as light the LED, reset  the indicator. Program Update (Upgrade online): Upgrade online for indicators.  Version: Users can query the version of the indicator.
  • Page 14: Parameters Query And Setting

    FPI-Hand Power Meter User Manual I-load (Load current): Load current of the indicator;  I-Fault (Fault current): Fault current of the indicator;  Batvalue (Battery voltage value): Battery voltage value of the indicator;  Temperature: Temperature of the indicator; ...
  • Page 15: Rf Parameters

    Earth Para: Earth protection parameters of the indicator;  Wave Para: Wave recording parameters of the indicator;  FPI Para: FPI-HAND parameters of the indicator.  3.4.4 RF parameters Move the cursor to “2.1 RFPara” , press [OK] to enter the following page: Description of “RFPara”...
  • Page 16: Running Para

    FPI-Hand Power Meter User Manual Freq (Frequency):1-30;  WakeUpT1 (Automatic wake up cycle):1-65535ms;  WakeUpT2 (Hold time for wake up ): 1-65535ms;  BaudRate (Baud rate): 100/25/10;  Tran-Level (Transmission power): 0:12dBm,2:10dBm,4:7dBm;  6:4dBm;8:1dBm;10:-2dBm Data-Mode:0/1/2  3.4.5 Running Para Move the cursor to “2.2 Running Para” ,press [OK] to enter the following page: Description of “Running Para”...
  • Page 17: Short-Circuit Protection Parameters

    FPI-Hand Power Meter User Manual Resend-Time WorkStatus BatThres (Battery low voltage threshold):2000-4000mV;  FieldThres (Electric field threshold): 1-65535;  I-Thres (Current threshold): 1-25.5A;  Down-Time:100-65535ms;  Flash-Time (Cyclic flashing time): 1-255s;  Light-Time (Duration of light on): 20-5000ms;  Upload-T1 (Interval of uploading): T1,10-65535s;...
  • Page 18: Earth Protection Parameters

    FPI-Hand Power Meter User Manual Reset-T 120s Repower-T Short-I 150.0A ShortIMax 0.0A Over-I 900.0A Steady-T PerDelay 3000ms ShortTMax 3000ms Short-T 20ms Reclose-T Reset-T (Timing reset delay) : 1-172800s;  Repower-T (Reset delay for power on): 1-65535;  Short-I (Short-circuit mutation): 1-1200A;...
  • Page 19: Wave Parameters

    FPI-Hand Power Meter User Manual Description of “2.4 Earth Para” are showed as below: 2.4 Earth Para Earth-Way Act-Pulse 10.0A Pulse-T1 800ms Pulse-T2 1000ms Act-Drop Relative-T Absolute-T 40ms Pas-pulse 10.0A Pas-Drop FieldDrop-T Earth-Way (Earth-fault judgement): 0-Passive,1-ActiveI,0x81-Active U;  Act-Pulse (Active pulse ): 1-600A;...
  • Page 20 FPI-Hand Power Meter User Manual Description of “2.5 Wave Para” are showed as below: 2.5 Wave Para Start-I 6.0A Stop-I 5.0A Lock-T Upload-T 4000ms Charge-T 10000s NumPre-W NumAfter-W Mutation-I 50.0A Mutation-U Fault-I 00030 Fault-U 00030 EnableFlag 07500 Start-I (Start current): Current threshold for start recording wave;...
  • Page 21: Fpi-Hand Parameters

    FPI-Hand Power Meter User Manual recording wave; Fault-I (Fault current): Current value that can judge fault;  Fault-U(Fault voltage): Voltage value that can judge fault;  EnableFlag (Enable flag): Enable flag that can start recording wave;  A-I: A coefficient that used to calculate ...
  • Page 22: Upgade Online

    FPI-Hand Power Meter User Manual LEDShut (Shutdown LED): The corresponding indicator light is off  Ctrl-Return (Flag reset): Reset the flag of the indicator  Ctrl-Action (Control flag): Control the indicator flag  Restart: Restart the indicator  ShortCircuit (Analog short circuit): The indicator will have short circuit action ...