CONFIGURATION

ATTENTION ! The operation of installation must be do by expert electrician.
The Control Unit can be set to have all the input or only someone.
With the DIP switch S3 it can be possible select:
1) Presence or not of Electronic key
2) Presence or not of Nozzle Contact
3) Complete bypass of electronic function. In this case the pump is switched ON when the Nozzle contact is close.
The nozzle contact remain the unique control for the pump activation.
With the trimmer TIMER can be set the maximum duration of dispensing
All the configuration are read at start-up. At the start-up the system determines the state of the trimmer TIMER and that of
the DIP-SWITCH of the BYPASS switch S3.
To change the Hardware Settings (Dip Switch And Timer ) proceed as follows:
i.
Disconnection power to the control unit;
ii.
Open the rear cover of the control unit;
iii.
Change the trimmer value (turning with a small flat-head screwdriver) and/or the switches of switch S3;
iv.
Close the rear cover of the control unit;
v.
Start the control unit again to make the new settings operative.
Min : 7 sec
UP ↑ ↑ ↑ ↑
DOWN↓ ↓ ↓ ↓
6ZLWFK
6ZLWFK
6ZLWFK
6ZLWFK
3RVLWLRQ
3RVL
WLRQ
           
3RVL
3RVL
WLRQ
WLRQ
,%XWWRQ
,%XWWRQ
,%XWWRQ
,%XWWRQ
Switch
UP ↑ ↑ ↑ ↑
UP ↑ ↑ ↑ ↑
DOWN ↓ ↓ ↓ ↓
Switch
(Factory Default for
DOWN ↓ ↓ ↓ ↓
all the switch)
SELECTION PROCEDURE:
- With the unit OFF, position the DIP switches according to wanted configuration
- Simultaneously keep Start and Stop keys pressed
- Switch-on the unit
- The key (3) LED will switch-on for 1 second to signal settings have been saved.
- Release the Start and Stop keys
$&&(66 
DANGER OF ELECTRICAL SCHOCK!
Max : 30 min
6ZLWFK
6ZLWFK
6ZLWFK
6ZLWFK
0HDQLQJ
0HDQLQJ
           
0HDQLQJ
0HDQLQJ
1R]]OH
1R]]OH
1R]]OH
1R]]OH
Electronic Key
Switch
Nozzle Contact
UP ↑ ↑ ↑ ↑
DISABLED
Switch
Electronic Key
Nozzle Contact
DOWN ↓ ↓ ↓ ↓
ENABLED
Pag 5 di 10
6ZLWFK
6ZLWFK
6ZLWFK
6ZLWFK
0HDQLQJ
0HDQLQJ
           
0HDQLQJ
0HDQLQJ
%RDUG
%RDUG
%RDUG
%RDUG
Electronic
Switch
UP ↑ ↑ ↑ ↑
DISABLED
DISABLED
Electronic
Switch
DOWN ↓ ↓ ↓ ↓
ENABLED
ENABLED
Manual Installation and Use
6ZLWFK
6ZLWFK
6ZLWFK
6ZLWFK
0HDQLQJ
0HDQLQJ
           
0HDQLQJ
0HDQLQJ
0HDQLQJ
0HDQLQJ
0HDQLQJ
0HDQLQJ
1&
1&
1&
1&
Switch
Control
UP ↑ ↑ ↑ ↑
Connected
Switch
Control
DOWN ↓ ↓ ↓ ↓
Connected
Not
Not

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACCESS 85 and is the answer not in the manual?

Questions and answers

Summary of Contents for Piusi ACCESS 85

  • Page 1 $&&(66  Manual Installation and Use CONFIGURATION ATTENTION ! The operation of installation must be do by expert electrician. DANGER OF ELECTRICAL SCHOCK! The Control Unit can be set to have all the input or only someone. With the DIP switch S3 it can be possible select: 1) Presence or not of Electronic key 2) Presence or not of Nozzle Contact 3) Complete bypass of electronic function.
  • Page 2 $&&(66  Manual Installation and Use Is It possible to have a table with state condition by DIP switch S3 and corresponding operational functioning DIP switch S3 Mode START Dispensing Mode STOP Dispensing Stop Stop Enabled by Start Dispensing Stop Enabled by Stop Dispensing with Dispensino with...
  • Page 3 $&&(66  Manual Installation and Use iv. If a User key is to be stored in the control unit memory, press the START key ( 1 ). Conversely, to delete a user I-Button key from the memory press the STOP key ( 0 ). This way, a work session is opened that will perform the same storage or cancellation operation for all the keys subsequently positioned.
  • Page 4 $&&(66  Manual Installation and Use Nozzle contact NO In this case the operating sequence is: 1. The operator position his electronic key, he is validated by the system and the pump starts up. The Key Led flashes for a little time. 2.
  • Page 5 $&&(66  Manual Installation and Use TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The Power Led does not light up - The system is not correctly power - Verify voltage electricity supplied network - Power connections are not correct - Verify power connections The motor does not start up - The electrical connections are not - Verify electrical connections...

Table of Contents