LAZER 150G PR-5030A This product manual contains important information about the safe installation and use of this projector. Please read and follow these instructions carefully and keep this manual in a safe place for future reference. PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, 511430 China...
Page 2
INDEX MAIN FEATURES SAFETY WARNING SAFETY PROTECTION FUNCTIONS SAFE USAGE OF THE PROJECTOR INSTALLING THE PROJECTOR POWER SUPPLY – MAINS OPERATION XLR CONNECTORS AND TERMINATOR DMX512 CONTROL DMX CONTROL CHANNEL FUNCTIONS OPERATIONS FOR DATA REFRESH MAINTENANCE ELECTRICAL DIAGRAM NOTICE Please note that as part of our ongoing commitment to continuous product development, specifications are subject to change without notice.
MAIN FEATURES: 1. Professional optical system dustproof technique, so need not periodic clean even if long time usage. 2. Uses international standard high speed vibratile lens whose scanning speed above 30K, make the scanning pattern more steady and exquisite. 3. Adopts the latest laser lamp of DPSS. 4.
PR-5030A OUTLOOK SAFETY WARNING The LAZER 150 PR-5030A belongs to the CLASS III-B laser product, the laser lamp parameter is as follows: Maximum output power:150 mW Beam length: 532 nm, green therefore Light spot size: <1.2mm Note of Safety Use 1: because the energy of this kind of laser is strong enough to result in the permanence injury to persons’...
SAFETY PROTECTION FUNCTIONS The laser safety protection measures of this product LAZER 150 PR-5030A are implemented according to the relative European items. These measures are as below: ▲ the cover open protection: open the plastic shell if there is current flows, the laser will be cut off automatically.
Page 6
The following points are important for safety as well as for the smooth installation and performance of the unit When unpacking and before disposing of the carton, check there is no transportation damage before using the projector. Keep the carton well for future possible transportation. Should there be any damage caused by transportation, consult your dealer and do not use the apparatus.
INSTALLING THE PROJECTOR Always ensure that the projector is firmly anchored to avoid vibration and slipping whilst functioning. Always ensure that the structure to which you are attaching the projector is secure and is able to support a weight of LAZER 150. For safety, the projector should have a secondary fixing with a safety chain through the holes on the underside of the unit.
OPERATION The unit uses standard DMX 512 controller. With the touch-switches and the digital display screen, DMX start address can be easily set and the various setup options may be configured. The display shows the DMX start address after the projector is switched on (if you have already set the DMX start address and saved it, the screen will display the last setting).
Once you have selected the desired operation code, press the key UP or DOWN to select “y” (means ON) or “no “(means OFF). N = NO, Y = YES. Press the key ENTER to save the selected function and configuration. If the display is showing “y”, then the setting has been enabled.
DMX TERMINATOR In the Controller mode or Master/Slave mode, the DMX output has to be connected with a DMX terminator at the last fixture in the chain. This prevents electrical noise from disturbing and corrupting the DMX control signals. The DMX terminator is simply an XLR connector with a 120Ω (ohm) resistor connected across pins 2 and 3, which is then plugged into the output socket on the last projector in the chain.
DMX CONTROL CHANNEL FUNCTIONS The LAZER 150 uses 16 DMX channels. They are listed in the following table. CHANNEL DMX VALUE DESCRIPTION 0-37 Unit OFF 38-74 Unit ON, animation 75-110 Unit ON, geometric picture 111-147 Unit ON, effect Unit ON/OFF 148-184 Unit ON, sound activation 1 185-221...
Page 12
0-15 Full range1/16 16-31 Full range2/16 32-47 Full range3/16 48-63 Full range4/16 64-79 Full range5/16 80-95 Full range6/16 96-111 Full range7/16 112-127 Full range8/16 Y Range adjust 128-143 Full range9/16 144-159 Full range10/16 160-175 Full range11/16 176-191 Full range12/16 192-207 Full range13/16 208-223 Full range14/16...
Page 13
X Range Adjust 16-31 Full range2/16 32-47 Full range3/16 48-63 Full range4/16 64-79 Full range5/16 80-95 Full range6/16 96-111 Full range7/16 112-127 Full range8/16 128-143 Full range9/16 144-159 Full range10/16 160-175 Full range11/16 176-191 Full range12/16 192-207 Full range13/16 208-223 Full range14/16 224-239 Full range15/16...
Page 14
224-239 240-255 0-15 Z rotation without direction change 16-31 32-47 48-63 64-79 Normal rotation from slow to fast 80-95 96-111 Z Rotation 112-127 on Sixteen 128-143 Z rotation without direction change 144-159 160-175 176-191 192-207 Reverse rotation from slow to fast 208-223 224-239 240-255...
Page 15
78-103 Strobe 3 104-129 Strobe 4 130-155 Strobe 5 156-181 Strobe 6 182-207 Strobe 7 208-233 Strobe 8 234-255 Strobe 9 (fast) Warning: when use DMX512 to control, some of picture under the edit effect may result in laser safe protection panel moving but without laser projection. That is the value of channel 4 or 15 is too large or the value of channel 5 or 6 is too small.
Page 16
Not used 0-15 Full range1/16 16-31 Full range2/16 32-47 Full range3/16 48-63 Full range4/16 64-79 Full range5/16 80-95 Full range6/16 96-111 Full range7/16 112-127 Full range8/16 X Range Adjust 128-143 Full range9/16 144-159 Full range10/16 160-175 Full range11/16 176-191 Full range12/16 192-207 Full range13/16 208-223...
OPERATION FOR DATA REFRESH 1. Connect the power cord and cable of data refresh with the unit, and the other end of the cable of data refresh connecting with a personal computer. Note: The power must be cut off before this operation.
ELECTRICAL DIAGRAM a) PR-5030A circuit diagram b) PR-5030A shape 18/21 Laser 100 manual_en.doc...
Page 19
c) PR-5030A assemblage d) PR-5030A back nog 19/21 Laser 100 manual_en.doc...
Page 20
Assembly Spec Item Name Description Main-board ZK4-02 V1.0 Reed Switch&Magnet 50V/1A Safe board LASER-SAFE V1.1 X-scanner moto Y-scanner moto X scanner serve amplifier SCAN-D1 V4.1A board Y scanner serve amplifier SCAN-D1 V4.1A board Multi-outputs switching IN AC85~250V OUT ± regulator 24V/1A,5V/1A Inter-lock board SAFE-LOCK V1.2...
Page 21
NOTICE 1. If peripherals or cable is damaged, please purchase it that is PR or LASER Company provided for change. 2. This software tests normally in the environment of win98, winxp and win2000. We do not provide the function guarantees if it is not under these operation systems. 3.