CHARGER OPERATION
CHARGING THE BATTERY PACK
Before using your PowerLuber for the first time, the battery
pack should be charged for 12 hours.
CHARGING PROCEDURE
Make sure power circuit voltage is the same as that shown
on the charger specification plate, Connect charger to
power source.
1. Plug the charger into an appropriate outlet before inserting
battery pack.
2. With the red light off, insert the battery pack into the charger.
The red (charging) light will blink continuously indicating that
the charging process has started.
3. The completion of charge will be indicated by the red light
remaining ON continuously. The pack is fully charged and
may be used at this time.
4. The battery pack may be left on the trickle charge until you
are ready to use.
5. Disconnect charger from power source when not in use.
INDICATOR LIGHT OPERATION
REPLACE BATTERY INDICATOR
The charger is designed to detect certain problems that can
arise with battery packs.
Weak battery pack - The red light flashes at a fast rate indicat-
ing a weak battery pack.
Shorted battery pack – With the charger plugged in and a bat-
tery is inserted the red light will not come on if the battery pack
is shorted.
If either of these problems occur, re-insert battery pack into the
charger. If the problem persists, try a different battery pack
to determine if the charger is O.K. If the new pack charges
correctly, then the original pack is defective and should be
returned to a service center or other collection site for recycling.
If the new battery pack elicits the same trouble indication as
the original, have the charger tested at an authorized service
center.
Americas:
One Lincoln Way
St. Louis, MO 63120-1578
USA
Phone +1.314.679.4200
Fax +1.800.424.5359
JUNE - 2006
Owner's Manual for Charger and Batteries
Europe/Africa:
Heinrich-Hertz-Str 2-8
D-69183 Walldorf
Germany
Phone +49.6227.33.0
Fax +49.6227.33.259
Form 402060
PowerLuber Battery Charger
LEAVING THE BATTERY PACK IN THE
CHARGER
The charger and battery pack can be left connected with the red
light glowing indefinitely. The charger will keep the battery pack
fresh and fully charged.
NOTE: A battery pack will slowly lose its charge when kept out
of the charger. If the battery pack has not been kept on main-
tenance charge, it may need to be recharged before use. A
battery pack may also slowly lose its charge if left in a charger
that is not plugged into an appropriate source.
As a battery pack approaches the discharged state, you will no-
tice a sharp drop in tool performance. When the tool is unable to
perform the task at hand, it is time to recharge the battery pack.
Recharging the battery pack before this condition is reached
will reduce the total work life of the pack. Discharging the pack
beyond this point can damage the pack.
NOTE: Battery temperature will increase during and shortly after
use. Batteries may not accept a full charge if they are charged
immediately after use. Allow the battery pack to cool to room
temperature before charging for best results.
CAUTION: Vent slots in top and bottom of charger must not be
obstructed. Do not charge battery when temperature is BELOW
32°F (0° C) or ABOVE 104°F (40° C).
PRODUCT SPECIFICATIONS
Input voltage range.................. 11 vdc to 28 vdc
Input current........................... 12 vdc @ 3.5 amps
Output................................... 14.4 vdc @ 2 amps
Time to Charge 1401 Battery..... 1 hour approximately
Cord Length........................... 6 ft (2 m)
Indicator Light ........................ Red
Weight.................................. 2.2 lb. (1.01Kg)
Asia/Pacific:
51 Changi Business Park
Central 2
#09-06 The Signature
Singapore 486066
Phone +65.6588.0188
Fax +65.6588.3438
Model 1415A
Series "A"
24 vdc @ 1.6 amps
© Copyright 2006
Printed in USA
Web site:
lincolnindustrial.com
Page Number - 1

Advertisement

loading

Summary of Contents for Lincoln 1415A

  • Page 1 Model 1415A PowerLuber Battery Charger Series “A” Owner’s Manual for Charger and Batteries CHARGER OPERATION LEAVING THE BATTERY PACK IN THE CHARGER CHARGING THE BATTERY PACK The charger and battery pack can be left connected with the red Before using your PowerLuber for the first time, the battery light glowing indefinitely.
  • Page 2 Model 1415A Battery Charger Important Charging Notes 1. Longest life and best performance can be obtained if the battery pack is charged when the air temperature is between 65°F and 75°F (18° - 24°C). DO NOT charge the battery pack in an air temperature below +40°F (+4.5°C) or above Don’t allow any liquid to get inside charger.
  • Page 3 PERSONAL INJURY OR FIRE. product using battery. 18. Dispose of expended batteries properly. The Lincoln Model 2. CAUTION: To reduce the risk of injury, Lincoln Model 1415A 1401 Battery Pack contains rechargeable, nickel-cadmium Charger should only be used to charge Lincoln battery pack batteries.
  • Page 4 In no event shall Lincoln be liable for incidental or consequential damages. Lincoln’s liability for any claim for loss or damages aris- ing out of the sale, resale or use of any Lincoln equipment shall in no event exceed the purchase price. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, therefore the above limitation or exclusion may not apply to you.

This manual is also suitable for:

A series