Materials Specifications:
Fabricated from 304 grade stainless steel. Engineered to attach over wood truss top chords, rafters and
I-Joists with a single grade 8 bolt. Designed as a permanent or temporary fall protection anchorage
device and compatible with all flashing systems supplied by
Specification of Use:
Fall Arrest or Fall Restraint for one person with a maximum body weight of 340lb (154kg ) including
Horizontal Lines
tools and equipment.
2x8/2x12-11 ga. anchors, workers must not be exposed to a free fall, and the system designed by a
"Qualified Person"*.
Part
Anchor SST
No.
Type
Ga.
Chord
#2830
2x4
14
2x4
#2801
2x8
14
2x6-2x8
#2802
2x12
14
2x10-2x12
#2805
2x8
11
2x6-2x8
#2806
2x12
11
2x10-2x12
Tile Roof
#2820
2x8
14
2x4-2x12
I-Joist
#1003
I-Joist
14
1-3/4"-2-3/4"
Moveable
#1014 *
2x8
11
2x4-2x8
#1015 *
2x10
11
2x10-2x12
Wall Mount
#1004
Standard
11
2x4-2x8
#1004-A
45/o
11
2x4-2x8
Z-Purlin
#1016
Standard
14
9-1/2"-2-3/4"
Flashing Systems:
Roofing
#2001- Santoprene*
All types
#2003- 2.5lb Lead
All types
#2020- Alum/EPDM
Tile
#2018- EPDM/Alum
Metal
Connectors:
Connecting hardware must comply with current standards.
Attach only through the "Connector Attachment Hole" shown
at
Fig.
2. See
Fig. 10a,b pg.3
for connector types.
Cutting/Severing Hazard
! Prevent lifelines/lanyards from
intersecting anchor stems.
Blocking 2x4 Top Chords:
2x8 anchors installed over 2x4 top chords or rafters
require a 24" length of 2x4 blocking. To prevent movement
attach blocking to the underside of the top chord as shown
in
Fig.
3. 2x8 anchors will provide greater resistance
to force loads than a 2x4 anchor.
Personal Protection Equipment / PPE:
PPE refers to the common types of personal safety
equipment typically required for fall protection: Harness,
Lanyard, Lifeline, Shock Absorber, and Rope Grab. The
use of a shock or energy absorbing device is required
anytime there is exposure to a free fall when
SAS
using
anchorage devices.
Component Compatibility:
SAS
anchorage devices are factory ensured for
PPE
compatibility with
manufactured by
must ensure component compatibility when using
equipment supplied by other manufacturers.
Framing Requirements:
Install onto top chords that are 2x4 or greater dimension.
Framing must be capable of supporting a 5,000lb (2,260kg)
load or 2 times the intended fall protection load.** Do not
install onto framing that is damaged or has spliced top chords.
* "Qualified Person" as defined by industrial safety standards. **As specified by OSHA 1926:502(d)(15)(i)(ii) or equal industrial standard.
Super Anchor Safety(SAS)
Multiple
or
Users on a single anchor: use only ARS
11 Gauge
Fits
Fastener
Pack
14 ga. anchors have a strength test rating of
more than 6,000lb (2,721kg).
have a strength test rating of more than 7,500lb
(3,400kg), to provide greater resistance to static
#2006
loading. Use for steep roofs or situations when
the anchor will be subjected to live loading.
Installation:
#2027
Anchors are supplied with (SAS) certified
grade 8 x 5/16" attachment bolts of sufficient
Detent Pin
length to allow a lock nut to be installed as
#2015
shown in
to stabilize the anchor position and prevent
#2014
movement during use.
#2014-A
Drill Through Method:
2x4/2x8/2x12/ I-Joist and Wall anchors may
#2019
Base
be installed by drilling through the top chord or
8x10"
rafter as shown in
16x16"
drill. DO NOT modify anchor by drilling additional
20x20"
bolt holes and do not enlarge factory bolt or teko
8x8"
nail holes.
Fig. 3
Blocking Under
2x4 Top Chord
SAS
. Users
and 14 Gauge:
11 ga. anchors
Fig.
3.
Use 6 ea. 1-1/4" teko nails
Fig.
1. Use a 5/16" (9mm)
Ridge
12.0" min.
From Ridge
2x4
Attach
Blocking
to Top Chord
2x4
Lock-nut
24.0" 2x4
Blocking
Sheathing:
Sheathing over top chords must be a minimum of 7/16" OSB or plywood and installed
over the anchor shoulders as shown in
under the top chord. If sheathing is already in place or if anchors are to be evacuated
after use, cut a 3"x 3" opening through the sheathing centered over the top chord.
WARNING TO USER:
Use Only Super Anchor Safety (SAS) Instruction/
Specification manuals for SAS equipment. You
must read this manual before you use this device.
Improper use can result in serious injury or
death. Consult SAS-07 or 2010 manual for more
information about fall protection.
Fig. 1
3"
Flashing
Riser
SAS
Factory
Supplied
Attachment
Bolt/Nut
#2006
Tile Roof
Anchor
Stem Height
8.0"
2x4
2x8
2x12
Stem
Height
6-1/2"
Teko Nails
3 ea. Leg
Leg
2x4
Grade 8
Attachment Bolt
2.0"
2-1/4"x 5/16" d.
Fig. 1
to allow the attachment bolt to be installed
By SCN 6/10 | Pg.1
Stem Cover
Tether
Strap
®
Santoprene
8"x10" Base
Flashing
Drill Through
2x6, 2x8, 2x10,
2x12
Fig. 2
Connector
Attachment
Hole
1-1/8"d.
Warning
l
Labe
Stem
Shoulder
Need help?