Quick Links

VT 5006BS20 Oransal Kart (Manual Opersyonlar için)
VT 5006BS20
Proportional Amplifier(for Manual The Operation)
Proportional amplifier VT-5005S 2X are suitable for controlling direct actuated
proportional directional control valves with the spool position feedback
4WRE10...-10/24
ⅠTechnical data:
1. Power supply: full bridge rectification 24V +10%-5%
2. Power: 50W
3. Control voltage: ±9V ±2%
4. Min.Load of the control voltage: 500Ω
5. Max. output current: 1800mA
6. Load resistance: 5.4Ω
7. Oscillating frequency: 2.5KHZ
8. Ramp time: 0.02S-5S
9. Ambient temperature: 0-40℃
10. Stability: ±8mA/8h
11. 0.5‰/Imax./℃
Remark: Abovementioned technical data has been preset. if you have special
requirement, please clarify when ordering
Ⅱ. How to use: Refer to connecting diagram
Amplifier and external wiring connection
1. The electrical supply should be D.C.24V
The point22A or 22C connected to the positive pole of the electrical supply.28A
or 28C connected to the negative pole of the electrical supply.
2. The connection of between the amplifier and solenoid.
The two ports of the proportional solenoid A should be connected to 2A
and 32A separately.
The two ports of the proportional solenoid B should be connected to 2C
and 32C separately.
Remark: (1).there is no directionality in the wire connecting.
(2). Solenoid A is the one with a shift sensor, Solenoid B is the one
without shift sensor.
3. The connection with the bit shift sensor: the amplifier should be
connected to the bit shift sensor with the shield cable.
10c should connect to the port 1 of the bit shift sensor.
30c should connect to the port 2 of the bit shift sensor.
8c should connect to the port ┴ of the bit shift sensor.
Screen all the input lines. Leave one end of the screen open. Connect
one end to 28A or 28C
4. The input of the control voltage signal
5. (1). 4 manual input ports for the input of voltage can be preset
The operation manual for VT-5006BS 2X
1
REV:0/07

Advertisement

loading

Summary of Contents for Dexter Laundry VT-5006BS 2 Series

  • Page 1 VT 5006BS20 Oransal Kart (Manual Opersyonlar için) VT 5006BS20 Proportional Amplifier(for Manual The Operation) REV:0/07 The operation manual for VT-5006BS 2X Proportional amplifier VT-5005S 2X are suitable for controlling direct actuated proportional directional control valves with the spool position feedback 4WRE10…-10/24 ⅠTechnical data: 1.
  • Page 2 VT 5006BS20 Oransal Kart (Manual Opersyonlar için) VT 5006BS20 Proportional Amplifier(for Manual The Operation) REV:0/07 a. When you use preset potentiometer P1 to input ±9V electric signal, 14C is signal input end, Switch on relay K1. It means short-circuit 24C(+24V) and 12C. b.
  • Page 3 VT 5006BS20 Oransal Kart (Manual Opersyonlar için) VT 5006BS20 Proportional Amplifier(for Manual The Operation) REV:0/07 0—9V, the nominal value should be 0-+6V. The position of the spool can be monitored according to real value. When the real value is - 30 - zero, the spool should be zero position.
  • Page 4 VT 5006BS20 Oransal Kart (Manual Opersyonlar için) VT 5006BS20 Proportional Amplifier(for Manual The Operation) REV:0/07...

This manual is also suitable for:

Vt 5006bs20