Download Print this page
Dexter Laundry VT-5004S 2X Operation Manual
Dexter Laundry VT-5004S 2X Operation Manual

Dexter Laundry VT-5004S 2X Operation Manual

Advertisement

Quick Links

VT 5004S 2X Oransal Kart (Manual Opersyonlar için)
VT 5004S 2X
Proportional Amplifier(for Manual The Operation)
Proportional amplifier VT-5004S 2X is used in the control of proportional flow
control valve with the spool position feedback 2FRE10 ( or 16 ) ——— -20/———
ⅠTechnical data:
1. Power supply: 24V +10%-5%
2. Power: 50W
3. Control voltage: ±9V ±2%
4. Load resistance: 10Ω
5. Max. output current: 2200mA
6. Ambient temperature: 0-40℃
7. Oscillating frequency: 2.5KHZ
8. Ramp time: 0.02S-5S
Remark: Abovementioned technical data has been preset. if you have special
requirement, please clarify when ordering
Ⅱ. How to use: Refer to connecting diagram
Amplifier and external wiring connection
1. The electrical supply should be D.C.24V
The point 6A or 6C connected to the positive pole of the electrical supply.10A
or 10C connected to the negative pole of the electrical supply.
2. The connection of between the amplifier and solenoid.
The two ports of the proportional solenoid should be connected to 2A
(or 2C) and 4 A (or 4C) separately.
Remark: there is no directionality in the wire connecting.
3. The connection with the bit shift sensor: the amplifier should be
connected to the bit shift sensor with the shield cable.
20c should connect to the port 1 of the bit shift sensor.
14c should connect to the port 2 of the bit shift sensor.
22c should connect to the port ┴ of the bit shift sensor.
Screen all the input lines. Leave one end of the screen open. Connect
one end to 12A or 12C
4. The input of the control voltage signal
(1). +9V control voltage (command electrical level) input port:
through the external potentiometer (resistance: 5K-10K ) input
the voltage signal 0-+9V voltage signal from 26C.
(2). +10V buffering simulated valve input port: programmable
controller or functional generator output the differential voltage
should be input from port 22A and 24C. 22A connect to high
level, 24C connect to low level. When the differential voltage up
to 10V, it is corresponding to the Max. position of the spool.
Caution: never connect to 22A and 24C to any port of the
::: Hidrosam Hidropar Hidrolik Pnömatik Elektronik San. ve Tic. Ltd. Şti. :::
Nilüfer Ticaret Merkezi Demirci Mah. 62. Sok. No:2 Nilüfer / BURSA / TÜRKĐYE
Tel : 90-224-441 88 77 Pbx Fax : 90-224-441 03 33 www.hidrosam.com info@hidrosam.com
The operation manual for VT-5004S 2X
1
REV:0/07

Advertisement

loading

Summary of Contents for Dexter Laundry VT-5004S 2X

  • Page 1 Proportional Amplifier(for Manual The Operation) REV:0/07 The operation manual for VT-5004S 2X Proportional amplifier VT-5004S 2X is used in the control of proportional flow control valve with the spool position feedback 2FRE10 ( or 16 ) ——— -20/——— ⅠTechnical data: 1.
  • Page 2 VT 5004S 2X Oransal Kart (Manual Opersyonlar için) VT 5004S 2X Proportional Amplifier(for Manual The Operation) REV:0/07 amplifier. It means that programmable controller (PLC) should not use the same power with the amplifier. The usage of the amplifier 1. This amplifier can supply +9V(16A, C) and –9V(14A or 26C) flat voltage. Besides self voltage supply, +9V can be supply voltage signal to external potentiometer.
  • Page 3 VT 5004S 2X Oransal Kart (Manual Opersyonlar için) VT 5004S 2X Proportional Amplifier(for Manual The Operation) REV:0/07 ::: Hidrosam Hidropar Hidrolik Pnömatik Elektronik San. ve Tic. Ltd. Şti. ::: Nilüfer Ticaret Merkezi Demirci Mah. 62. Sok. No:2 Nilüfer / BURSA / TÜRKĐYE Tel : 90-224-441 88 77 Pbx Fax : 90-224-441 03 33 www.hidrosam.com info@hidrosam.com...