ANTAIRA DTD-360-0953-T Hardware Manual

360w industrial dc to dc power booster, 9~36vdc power input
Hide thumbs Also See for DTD-360-0953-T:

Advertisement

Quick Links

DTD-360-0953-T
360W Industrial DC to DC Power Booster, 9~36VDC Power Input,
53VDC Power Output, -40°C ~ 75°C
Hardware Manual
Version 1.0
(April 2023)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DTD-360-0953-T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ANTAIRA DTD-360-0953-T

  • Page 1 DTD-360-0953-T 360W Industrial DC to DC Power Booster, 9~36VDC Power Input, 53VDC Power Output, -40°C ~ 75°C Hardware Manual Version 1.0 (April 2023)
  • Page 2 Antaira Technologies, LLC will not be liable for any technical inaccuracies or typographical errors found in this guide. Changes are periodically made to the information contained herein and will be incorporated into later versions of the manual.
  • Page 3 Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 Caution: Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment. Avertissement FCC Cet équipement a été testé et déclaré conforme aux limites d'un appareil numérique de classe A, conformément à la partie 15 des règles de la FCC.
  • Page 4 Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 This document is the current official release hardware manual. Please check our website (www.antaira.com) for any updated manual or contact us by e-mail (support@antaira.com).
  • Page 5: Table Of Contents

    Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 Table of Contents 1 Overview 1.1 Product Hardware Features 1.2 Package Contents 1.3 Safety Precaution 2 Hardware Description 2.1 Physical Dimensions 2.2 Front View Panel 2.3 Top View Panel 2.4 LED Indicators...
  • Page 6: Overview

    Antaira Technologies’ DTD-360-0953-T is a DC/DC Output DIN rail mounted power booster that provides up to 360 watts of power. It is designed in compact size IP30 metal housing. DTD-360-0953-T with the booster technology is the best solution for the applications with low voltage power source available. Besides, the -40°C to 75°C wide temperature range design makes it perfect for operating in critical industrial environments, like automation and motivative.
  • Page 7: Safety Precaution

    Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 1.3 Safety Precaution Attention: If the DC voltage is supplied by an external circuit, please use a protection device on the power supply input. The industrial power booster’s hardware specs, ports, cabling information, and wiring installation will be described within this hardware manual.
  • Page 8: Hardware Description

    Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 2 Hardware Description 2.1 Physical Dimensions Figure 2.1, below, shows the physical dimensions of this product series: (W x D x H) is 30mm x 75mm x 95mm...
  • Page 9: Front View Panel

    Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 2.2 Front View Panel Figure 2.2, below, shows the front panel of the product series: Figure 2.2 - Front View Panel 2.3 Top View Panel Figure 2.3, below, shows the top panel of the product series:...
  • Page 10: Led Indicators

    Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 2.4 LED Indicators There are LED light indicators located on the front panel of the industrial power booster that display the power status. Each LED indicator has a different color and has its own specific meaning, see below in Table 2.1.
  • Page 11: Wiring The Power Outputs

    Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 Caution: Only use copper conductors, 125°C, tighten to 7 lbs. The wire gauge for the terminal block should range between 18~20 AWG. Attention: Utilisez uniquement des conducteurs en cuivre, 125°C, serrez à 7 lb.
  • Page 12: Grounding Note

    Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 Figure 2.8 - Adjustable Knob for Power Output Voltage 2.7 Grounding Note Grounding and wire routing help limit the effects of noise due to Electromagnetic Interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting devices.
  • Page 13: Mounting Installation

    Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 3 Mounting Installation 3.1 DIN-Rail Mounting The DIN-Rail is pre-installed on the industrial power booster from the factory. If the DIN-Rail is not on the industrial power booster, please see Figure 3.1 to learn how to install the DIN-Rail on the switch.
  • Page 14: Wall Mounting

    Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 Figure 3.2 - Insert the Switch on the DIN-Rail Figure 3.3 - Stable the Switch on the DIN-Rail 3.2 Wall Mounting Follow the steps below to mount the industrial power booster using the wall mounting bracket as shown below in Figure 3.4.
  • Page 15 Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 Figure 3.4 - Remove DIN-Rail bracket from the Power Booster Below, in Figure 3.5 are the dimensions of the wall mounting bracket. Figure 3.5 - Wall Mounting Bracket Dimensions...
  • Page 16: Hardware Installation

    Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 4 Hardware Installation 4.1 Installation Steps This section will explain how to install the industrial power booster: Caution: This device is intended for indoor use. Attention: Cet appareil est destiné à une utilisation en intérieur.
  • Page 17: Maintenance And Service

    If the power indicator LED does not turn on when the power cord is plugged in, the user may have a problem with the power cord. Check for loose power connections, power losses or surges at the power outlet. ◆ Please contact Antaira for technical support service, if the problem still cannot be resolved. ●...
  • Page 18 Antaira Technologies - Industrial Power Booster DTD-360-0953-T - Hardware Manual - v1.0 www.antaira.eu info@antaira.eu www.antaira.com.tw info@antaira.com.tw Any changes to this material will be announced on the Antaira website.

Table of Contents