Connect & Mount Terminal
Connect & Mount Terminal
2
1
1
3
5
To mount terminal.
4
Hold mounting bracket flush against wall with
cable access cutout towards floor. Note: The
bottom of bracket should be approximately 45
inches from floor. Allow for 6ft long cable.
Level bracket & mark four screw holes close to
corner tabs.
Drill holes as marked and insert included anchors
if needed.
Screw mounting bracket to wall with included
screws.
Drill hole centered in rectangular opening of
bracket for cables. The hole should be large
enough to route cables through wall.
Push terminal onto mounting bracket aligning
four tabs on bracket with four matching slots on
back of terminal.
Be sure to write down the
terminal serial number before mounting.
Setup Cont.
2
Click "Pay Class" from the "Setup" drop down menu. A default Pay Class has been set up. Click "Edit" to
review all settings. Click "Save & Close". If additional Pay Classes are needed, click "Add Pay Class" and
complete required fields (*). Click "Save & Close".
3
Click "Employee Group" from the "Setup" drop down menu. Click "Add Employee Group" and complete
required fields (*). Click "Save & Close". Repeat if additional Employee Groups are needed.
Start time should be one hour after last Out punch of previous pay period and one hour before first In punch of current pay period.
Connect Ethernet cable into Ethernet
1
port located in compartment on back
of terminal.
Connect power supply into power port
2
located in compartment on back of
terminal.
Route the cables through channel at base
3
of terminal.
4
Mount terminal (see instructions below).
Plug free end of Ethernet cable into
5
network jack, router or switch.
Plug free end of power supply into
6
outlet.
6
Slide terminal downward until locking tab clicks
into place. When properly mounted, terminal
cannot be slid up and off bracket without using
included wall bracket release key to disengage
locking tab.
To detach terminal.
Hold wall bracket release key with pointed end
up & diagonally cut side away from you.
Insert key into narrow slot located on bottom of
terminal to right of cable access cutout.
Push key all the way up into slot. Key will slide
easily until last ½ inch until some resistance from
locking tab is felt.
With key fully pushed into slot, slide the terminal
up and off mounting bracket.
Install TimeTrax™ Software
1
Insert TimeTrax™ DVD into CD-ROM drive.
Run Install Wizard and click "Finish" when
installation is complete.
Installation may
take 15 minutes or longer to complete
depending upon other installed applications.
Password may be changed after Setup is complete by clicking Administration/User Accounts from tool bar.
Setup
1
IMPORTANT: Click "Help" from the main toolbar to access index
of help topics, or click "F1" for help on a specific screen.
Click on "Company" from the "Setup" drop down menu.
Complete required fields (*) then click "Save & Close".
Required fields (*) must be completed during initial Setup. Optional fields can be completed at any time.
Setup Cont.
4
Click "Employee Profile" from the "Setup" drop down menu. Click "Add Employee" and complete
required fields (*). Click "Add Card" to enter proximity badge number. Click "Save" then click "Save &
Close". Repeat to add employees.
Using Time Clock
Wave prox badge within two inches of target area.
If employee badge number is successfully read,
the time clock terminal will beep and the badge
number will be displayed briefly on terminal
screen.
Employee records generated from prox badge
punches are stored within the terminal. The ter-
minal stores the last 6,000 punches before down-
load is required. Depending upon usage, punches
can be retrieved on a more or less frequent basis.
2
LOGIN
Please login with your Login ID and Password.
Login ID *
ADMIN
Password*
* Required Fields
LOGIN
Enter Login ID "ADMIN".
Enter Password "PTI" (case sensitive).
Click "LOGIN".