7. Nuisance Alarms and Hush Function

This alarm is designed to minimise nuisance alarms. Cigarette smoke will
not normally cause the unit to alarm, unless the smoke is blown directly
into the alarm. Combustion particles from cooking may set off the alarm
if it is located too close to a cooking appliance. Large quantities of
combustible particles are generated from spills or when boiling. Using
the fan on a range hood which vents to the outside (non-recirculating
type) will also help prevent nuisance alarms from occurring by removing
these combustible products from the kitchen.
HUSH
If you know why the alarm is sounding, and you can verify that it is not
a life threatening situation, you can push the button on the alarm to
silence the alarm for up to 11 minutes. If the smoke is not too dense,
that alarm will silence. After the Hush period, the smoke alarm will
automatically reset and sound the alarm if particles of combustion are
still present. You can use Hush repeatedly until the air has been cleared
of the condition causing the alarm.
Note: Dense smoke will override Hush and sound a continuous
alarm. If no fire is present, check to see if one of the reasons listed
in page 7. LOCATIONS TO AVOID may have caused the alarm. If a fire
is discovered, exit the building and call the fire brigade.

8. Alarm Visual and Audible Indicators

The following tables describes the visual and audible alarm conditions
the unit may report and illustrates how the unit will indicate normal
standby, alarm and error conditions.
Alarm
Mode
Smoke
or Fire
detected
If you require further information please contact Service on 1800 654 435
or visit our website at www.quell.com.au.
10
Model
Living Area
Model P3010L
Part No. 135986
Bedroom with Voice
Model P3010B
Part No. 135987
Hallway with
Emergency
Safety Light
Model P3010H
Part No. 135988.
Visual Indications
3 blinks
synchronized with
audible alarm
3 blinks
synchronized with
audible alarm
3 blinks
synchronized with
audible alarm
& amber light
illuminated
Audible
Indications
3 long
beeps(ISO8201),
repeating
3 long
beeps(ISO8201),
repeating with
voice "Fire"
announced
3 Long beeps(ISO
8201), repeating