Page 3
. Built-in Calculator ....25 . LHOLE Function ....... 31 . INCL Function ......37 . PCD Function ......47 . R Function ........ 55 . Simplified R Function ....73 . Shrinkage Calculation ..... 91 . ES-1M Setup Function ..99...
Page 90
ARC starting point R's deepest point = 200 - 200 - 60 = 9.210 mm step 1 : select work plane : plane R S.R - XZ enter into XZ plane Simpflified R function select work plane Easson ES-1M - 86 -...
Page 91
Easson Simplified R function Simplified R function Simplified R preset type TYPE 1-8 select preset type TYPE 1-8 step 2 : For the first part select preset type TYPE = 6 select type TYPE 1-8 next step TYPE 1-8 TYPE 1-8...
Page 92
Easson Simplified R function Simplified R function step 5 : enter Z increment per step machining ES-1 provides two options on the Z increment per step machining. Operator can make their selection on the smooth R function. Option 1 : Fixed Z step (...
Page 93
Z dial turn number 0.00 move the Z axis according to the dial Z dial reading settings displayed on Y axis Easson ES-1M Display data in plane machining mode If the axis is positioned outside the curvature, ES-1 will display "...
Page 94
Z STEP increment can be change anytime during the ARC machining increment = currently Z STEP 0.3 mm change the Z STEP Z STEP Easson ES-1M now the Z STEP increment 0.5 mm Change Z STEP increment to 0.5 mm...
Page 103
Easson- Always Committed to Quality, Technology & Innovation ES-1/1M Digital Readout Setup Function 987.165 125.885 245.315 Easson ES-1M - 99 -...
Page 105
E S - 1/1 M O RIGIN AL PARAMETER RESET FUNCTION 987.165 125.885 245.315 Easson ES-1M Some inscrutable cases or improper operations cause the chaos of parameter, then you need to initialize the parameter to reset the system. Operational procedure: 1...
Page 106
( ) The reset of parameter has completed then start to enter into the test procedure of display light. 88888888 88888888 88888888 88888888 Easson ES-1M 5 ( ) Turn off the DRO after complete the reset, then power on the DRO once again. - 102 -...
Page 107
Procedure: 1). Turn off the ES-1 or ES-1M. 2). Power on the ES-1 or ES-1M once again, when the message "ES-1" or "ES-6" showing in the MESSAGE WINDOW, please press the letter E of the Easson logo in the left bottom of the key panel immediately, then into the SETUP function.
Page 108
SETUP SLEEP Easson ES-1M Easson ES-1M Press key into the sleep mode function. Press the DOWN key once and the message "SLP ON" appears in the MESSAGE WINDOW. Press the DOWN key again, the words "SLP OFF"...
Page 109
REF SIGN = 0 REF SIGN = 1 Normal Voltage = 0V Normal Voltage = 5V At ref point = 5V At ref point = 0V Suppliers-Easson, Mitutoyo, Futaba Suppliers-Fagor When fitting an EASSON scale always set to 0 - 105...
Page 110
"Z DIAL" function. REF SIGN Z DIAL Easson Easson ES-1M ES-1M Press key into the setting function, i.e. your setting value is "2.500mm". Z DIAL Z DIAL 2.500 Easson...
Page 111
Easson 9.) Press key to select the "Z MOVE" function. DIALINC Z MOVE Easson Easson ES-1M ES-1M Press key into the setting function, the message "TAB MOV" is shown in the MESSAGE WINDOW. Z MOVE TAB MOV Easson Easson ES-1M...
Page 112
Easson AXIS NO AXIS NO AXIS NO Easson ES-1M Easson Easson ES-1M ES-1M After entering the SETUP mode shown overleaf, push the UP/DOWN keys on the keypad until the word "AXIS NO" is shown in the MESSAGE WINDOW. Press the ENTER key to access the next menu level.
Page 113
13.) Press key to make your setting, then press key to select the "NORMAL" function. DRO TYPE AXIS NO NORMAL Easson ES-1M Easson Easson ES-1M ES-1M Press key into the setting function, the meassage "DEFAULT" is shown in the MESSAGE WINDOW.