Download Print this page

Advertisement

Quick Links

Easson
Always Committed to Quality Technology & Innovation
ES-3
DRO Counter
Operation Manual
Easson Technologies Co., Ltd.

Advertisement

loading

Summary of Contents for Easson ES-3

  • Page 1 Easson Always Committed to Quality Technology & Innovation ES-3 DRO Counter Operation Manual Easson Technologies Co., Ltd.
  • Page 3 Easson Easson Easson Easson Easson Easson 、 B a s i c F u n c t i o n ....Easson Easson 、 R E F d a t u m m e m o r y F u n c t i o n ..
  • Page 5: Basic Functions

    Easson Easson Basic Functions 987.035 852.765 987.035 Easson ES-3 - 1 -...
  • Page 7 Easson Easson Set Display to Zero Purpose : Set the current position for that axis to zero Example : To set the current X Axis position to zero 12.345 0.000 5.000 5.000 Inch / Metric Display Conversion Purpose : Switches between inch and metric display...
  • Page 8: Enter Dimensions

    To set the current X Axis position to 45.800 mm 0.000 12.345 987.035 Easson ES-3 0.005 / 0.01 resolution display switches Purpose : Switches between 0.005mm/(0.0002") and 0.01mm(0.0004") resolution display 0.005mm 0.01mm Example 1 : Currently in display resolution, to switch to display resolution 56.785...
  • Page 9 The operator is then free to zero the axes or preset any dimensions into any axis in INC coordinate for relative position machining. The work piece datum ( work piece zero position ) is still retained in ABS coordinate by the ES-3. Operator can then toggle between ABS (absolute) and INC (incremental) coordinates without losing the work piece datum ( work piece zero position ).
  • Page 10 Easson Centre-find Purpose : ES-3 provides the centre-find function by halving the current display coordinate, so that the zero point of the work piece is located at the centre of the work piece. Example : To set the X Axis zero point at the centre of the work piece.
  • Page 11 Easson Easson datum memory - 7 -...
  • Page 13 (zero position) can be recovered by presetting this distance from the mark position. Operation : ES-3 provides one of the most easy-to-use datum memory function. There is no need to store the relative distance between the mark and your work datum...
  • Page 14 : X, Y, Z respectively step 3 : move the machine reader head across the length of the transducer until digits display in ES-3 start to count. move the machine 0.000 1.250 until...
  • Page 15 ES-3 starts to count, then the work piece datum is recovered move the machine 0.000 1.250 until ES-3 's digits display start run Easson ES-3 Easson ES-3 move the machine across the length of the transducer - 11 -...
  • Page 17 Easson- Always Committed to Quality, Technology & Innovation ES-3 Digital Readout Setup Function 9 8 7 . 0 3 5 8 5 2 . 7 6 5 9 8 7 . 0 3 5 Easson ES-3 - 13 -...
  • Page 19 1 ( ) Turn off the ES-3. 2 ( ) Power on ES-3 once again, when "ES-3" moving in display window, please press "8" key then ES-3 enters into the RESET function. 8 8 8 8 8 8 8 8...
  • Page 21: Setup Function

    SETUP the DRO. Procedure: 1). Turn off the ES-3. 2). Power on the ES-3 once again, when the message "ES-3" showing in the MESSAGE WINDOW, please key immediately then the DRO ES-3 starts entering into the SETUP function.
  • Page 22 "LC" (linear compensation) function. 1 . d i r 2 . L C 3 . r - d Easson ES-3 Easson ES-3 : The formula of linear error compensation error value *-(1000/measuring length) = compensation value μ...