Download Print this page

Meilhaus Electronic MEphisto Scope UM202 Quick Start Manual

2 channel usb scope
Hide thumbs Also See for MEphisto Scope UM202:

Advertisement

Quick Links

Warnings
The "MEphisto Scope" has a maximum input voltage of ±10 VDC. Measuring higher voltages
than this directly may damage the instrument and invalidate the warranty.
!
The "MEphisto Scope" is not
galvanically isolated, i. e. in
online operation the ground
of the device connects directly to the ground
of the PC via the USB cable. If you are using a
standard desktop PC the ground of the device
connects to earth by the power cable (with
earthing contact). However, this reference
to earth potential is missing in case of con-
nection with a laptop or in offl ine operation.
Therefore a good earthing via the earth
contact at the rear of the housing and
special caution are strictly necessary for
your own safety!
To measure high voltages such as mains supplies use a high voltage differential probe for your personal safety
and to prevent damage to the instrument. Please follow the appropriate standards, installation instructions
and national safty standards. Meilhaus Electronic GmbH assumes no responsibility for damage in case of
faulty installation, operation or handling.
What's in the Box?
Please make sure, that your "MEphisto Scope" box includes the following items:
• 1 x USB scope "MEphisto Scope" (UM202, UM203) hardware.
• SD memory card (UM203 only).
• CD with driver and DAQ software "MEphistoLab".
• USB cable (type A - type B)
• Getting Started Guide.
Accessories (optional)
"ME-Probe LF Pair"
2 passive modular probes (1:1/1:10 selec-
table) with accessories. Bandwidth: 15/150
MHz, 47/15.5 pF, 1/10 MΩ, 600 Vp CAT I.
"ME-UB" series
Connect up to 3 "ME-UB" boxes to the 26pin
D-sub with a triple break-out cable "ME AK-
DUB/UM202".
Available models: terminal block, opto-isolated inputs, opto-isolated outputs, relays
Support
Should you experience problems with the device or software, please
send an E-Mail to support@meilhaus.com.
Newest infos and software updates on our web site: www.meilhaus.com.
Earth contact
2 x
2 x
2 Channel USB Scope "MEphisto Scope"
(UM202, UM203)
Quick Start Guide
Meilhaus Electronic GmbH
Fischerstrasse 2
82178 Puchheim/Germany
E-Mail sales@meilhaus.com
Web
www.meilhaus.com
¤
+49 - 89 - 89 01 66-0
FAX
+49 - 89 - 89 01 66-77
Revision: 1.6
All trademarks acknowledged.
Information contained in this
document is subject to change
without notice.

Advertisement

loading
Need help?

Need help?

Do you have a question about the MEphisto Scope UM202 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Meilhaus Electronic MEphisto Scope UM202

  • Page 1 To measure high voltages such as mains supplies use a high voltage differential probe for your personal safety and to prevent damage to the instrument. Please follow the appropriate standards, installation instructions and national safty standards. Meilhaus Electronic GmbH assumes no responsibility for damage in case of faulty installation, operation or handling.
  • Page 2 “MEphisto Scope” - Features Installation “MEphisto Scope” is a mobile multi-functional device in a compact sheet steel box. 1. Connect the “MEphisto Scope” to a USB port of your PC using the USB cable included with the device. ⇒ The hardware wizard will automatically detect the The module is powered from the PC via the USB interface;...

This manual is also suitable for: