Overview
Thank you for purchasing an F-Drive Boomtabatty-Box4 (B-Box4). B-Box4 takes a single four-channel
RJ45 output from an F-Drive R12 output card or W1 Driver and provides four separated output
channels to support luminaires or loads in star topology. B-Box4 is compatible with F-Drive R12 with a
CC-150 Card or FTW-150 Card, F-Drive W1 CC Driver, or W1 Fade to Warm Driver and connects to
ArcSystem Navis 100 Fixed White or Fade to Warm luminaires, ArcSystem Pro One-Cell luminaires, or
third-party loads.
Note:
local jurisdiction requirements.
For more information on compatible products, see the resources below:
F-Drive System Design Tool
The F-Drive System Design Tool
Drive-System-Design-Tool.aspx) allows you to design an F-Drive R12 rack unit or F-Drive W1 driver
with different luminaires, breakout boxes, cable lengths, and other system components.
LED Dimming Compatibility Database
The LED Dimming Compatibility Database (etcconnect.com/compatibility/) is a searchable list of
devices that ETC has tested for compatibility with ETC dimming and control systems.
Documentation for Compatible Products
The following documents are available at
Drive/Documentation.aspx:
F-Drive Series R12 Installation Manual
F-Drive Series W1 Installation Manual
F-Drive R12 and W1 Wiring Reference Guide
The following documents are available at
Navis/Documentation.aspx:
ArcSystem Navis 100 Installation Guide
The following document is available at
Cell/Documentation.aspx:
ArcSystem Pro D1 and D2 Series Drivers Installation Guide
The following document is available at
Fixtures/ArcLamp/Documentation.aspx
ArcLamp System Installation Manual
Corporate Headquarters
Global Offices
New York, NY
Web
© 2021 ETC
Product information and specifications subject to change. ETC intends this document to be provided in its entirety.
7148M2120 Rev A Released 2021-11
If used within an Emergency Lighting Circuit, follow NEC marking requirements or
(etcconnect.com/Products/Power-Controls/LED-Drivers/F-Drive/F-
n
Middleton, WI, USA
n
|
London, UK
Rome, IT
|
|
Orlando, FL
Los Angeles, CA
etcconnect.com
|
Support
support.etcconnect.com
|
Trademark and patent info:
etcconnect.com/Products/Power-Controls/LED-Drivers/F-
etcconnect.com/Products/Lighting-Fixtures/ArcSystem-
etcconnect.com/Products/Lighting-Fixtures/Pro-One-
etcconnect.com/Products/Lighting-
|
+1 608 831 4116
|
|
|
Holzkirchen, DE
Paris, FR
Hong Kong
|
Austin, TX
|
Contact
etcconnect.com/contactETC
etcconnect.com/ip
|
|
Dubai, UAE
Singapore

Advertisement

loading

Summary of Contents for ETC F-Drive B-Box4

  • Page 1 Orlando, FL Los Angeles, CA Austin, TX etcconnect.com Support support.etcconnect.com Contact etcconnect.com/contactETC © 2021 ETC Trademark and patent info: etcconnect.com/ip Product information and specifications subject to change. ETC intends this document to be provided in its entirety. 7148M2120 Rev A Released 2021-11...
  • Page 2 Database at etcconnect.com/compatibility/ to see if your load is compatible. If your load is not in the compatibility database, follow the instructions at the link above to contact the ETC Applications Engineering department to arrange for compatibility testing. F-Drive B-Box4...
  • Page 3 ETC Installation Guide F-Drive B-Box4 Drive ArcSystem Navis Luminaires with a FD-BBOX-4R Drive up to four Navis Fixed White or Fade to Warm luminaires with a FD-BBOX-4R and an F-Drive. Visit the F-Drive System Design Tool at etcconnect.com/Products/Power-Controls/LED-Drivers/F- Drive/F-Drive-System-Design-Tool.aspx to learn more.
  • Page 4 ETC Installation Guide F-Drive B-Box4 Note: Navis luminaires will not function if they are FD-BBOX-4R daisy-chained off of each other from the output of the B-Box. Drive ArcSystem Pro One-Cell Luminaires with a FD-BBOX-4M Drive up to four ArcSystem Pro standard, Small, or Micro luminaires with a FD-BBOX-4M and an F-Drive.
  • Page 5 LED Dimming Compatibility Database at etcconnect.com/compatibility/ to see if your load is compatible. If your load is not in the compatibility database, follow the instructions at the link above to contact the ETC Applications Engineering department to arrange for compatibility testing. Note: If used within an Emergency Lighting Circuit, follow NEC marking requirements or...
  • Page 6 • Parts and Tools The following supplies are required, but not provided: Optional Breakout Box Mounting Kit (ETC part number 7148K1018) to surface-mount the B-Box4 • or to secure it with a lanyard Two M5 (#10) screws or other mounting hardware as needed •...
  • Page 7 ETC Installation Guide F-Drive B-Box4 Electrical and Wiring Specification Connector/ Connector/ Torque B-Box4 Model Wire Range/Specifications Strip Length Port Name Port Type Rating You must use 0.25 mm (23 AWG) or larger RJ45 Terminate to T568B standard. conductors in Category-type cable.* You must use 0.25 mm (23 AWG) or larger...
  • Page 8 Mounting Accessories Surface-mount: use the mounting plate only (ETC part number 7148A3051) • Hang: use the breakout box mounting kit (ETC part number 7148K1018) with mounting plate • and 457 mm (18 in) tether Install the Mounting Plate In order to surface-mount the B-Box4 or attach the tether, you must install the mounting plate.
  • Page 9 ETC Installation Guide F-Drive B-Box4 Hang the B-Box4 The tether has an eye at both ends and one J-hook spring clip. You can use it in two ways: clip the tether to the B-Box4 mounting plate and attach the eye on the...
  • Page 10 ETC Installation Guide F-Drive B-Box4 Connect Luminaires or Loads to a B-Box4 Complete the steps below for your model of B-Box4 to connect luminaires or loads to the four outputs. FD-BBOX-4R Note: You must use 0.25 mm (23 AWG) or larger conductors in Category-type cable. Not all Cat5 or Cat6 cables meet this requirement.
  • Page 11 ETC Installation Guide F-Drive B-Box4 FD-BBOX-4T 1. Prepare the wires for the provided screw-terminal plugs (ETC part J3388-F). Electrical and Wiring Specification on page 7 for the wire gauges accepted by the screw- • terminal connectors and strip the wires according to the strip length listed.

This manual is also suitable for:

Fd-bbox-4rFd-bbox-4mFd-bbox-4t