Swing Operation - Fujitsu ASYG07KGTF Service Manual

Table of Contents

Advertisement

4-3. Swing operation

• To select up/down airflow swing operation
When the swing signal is received, the horizontal louver starts to swing.
– Swinging range
• Cooling mode/dry mode/fan mode (1 to 3): 1 ↔ 4
• Heating mode/fan mode (4 to 6): 3 ↔ 6
– When the indoor fan is S-LOW or stop mode, the swing operation is interrupted and it stops at
either upper end or bottom end.
• To select left/right airflow swing operation
No function
4-3. Swing operation
- (04-17) -
4. Louver control

Advertisement

Table of Contents
loading

Table of Contents