3. Batch Timer - Timer activated by the Force On/Off key for a user defined run time. 4. Other timer types are selectable but should not be used for AFS systems.
III. Installation Electrical Wiring The controller has an internal regulated power supply that will operate in the range of approximately 100 to 240 VAC on the incoming wiring. Output relay 2 is protected with a replaceable fuse. Relay output voltage will equal the incoming line voltage.
3. Never attempt to land connections to the controller without first disconnecting power from the outlet. 4. Do not block access to disconnect power during mounting and installation. 5. The controller should be connected to its own isolated circuit breaker, and for best results, the ground should be a true earth ground, not shared.
Front Panel Description Press MENU to access menus or go back one layer in menu structure. MENU Wed 10:59:57am Press FORCE to activate relays manually again for Off and a third time back to auto. FORCE ON/OFF Press ENTER to go a layer deeper in menu, ENTER to initiate a setting change and to set change.
Page 6
Calibration Bleed Set Timer Set Water M Cal Temp 077°F Continuous Setpoint 00100 Pulse Run After 0010 Password 0000 Reset Me Cal 02500µS Diff 010 Run Time mm:ss Flow Sw: Close Meter U Force Bleed? N Direction: Rise Post Bleed 010% of Bld Drum Lvl: Off Meter V...
Diagnostics Water Meter Clock Set Force Set 4-20 Output 4mA=00100 Nano-C Reset Meter? N Set Time Force On: Ask Force On: Both 20mA=01000 FW: ?.?.? Meter Units Set Date Force On: Tmr SIM 20: 2960 Test Keypad Meter Value Set Day & Week Force On: Bld SIM 4: 0700 Test Display...
VII. Manufacturer’s Product Warranty Advantage Controls warrants units of its manufacture to be free of defects in material or workmanship. Liability under this policy extends for 12 months from date of installation. Liability is limited to repair or replacement of any failed equipment or part proven defective in material or workmanship upon manufacturer’s examination.
Need help?
Do you have a question about the AFS Systems and is the answer not in the manual?
Questions and answers