LightViper VIM‐1808 / 0808 Specifications
Specifications
• 8 x 8 fiber optic transport system
• Cable runs over 1.25 miles with no loss
• Rugged, lightweight fiber cable
• 24 bit / 96kHz sampling (24/48k with ext. input)
General Specifications
Total Harmonic
Less than 0.01%
Distortion + Noise*1
Frequency Response
± 0.5 dB
Dynamic Range
102 dB
Crosstalk
5 dB above noise floor
Sampling Rate
24 bit / 96kHz or 24 bit / 48 kHz
630 s one way, analog input to digital output, 20 s one way, digital input to digital output.
Latency
Operating Temp
0 to +50°C ambient temperature.
Sync LED
LED (green) indicates optical link OK, LED (red) indicates problem with optical link, LED (off) indicates no power.
AC Power
Universal 90‐250 VAC, 50/60 Hz, IEC connector with fuse
Max Current Rating
VIM‐1808 / VIM‐0808
On / Off Control Date +
RJ‐45 connector for logic level control, CMOS or TTL at 2 MHz max per channel.
MIDI
Dimensions
VIM‐1808 / VIM‐0808
Weight
VIM‐1808 / VIM‐0808
300 ft Fiber Cable (tactical)
*1‐Hum & Noise are measured with an AES17 compliant filter at 20 kHz. Temperature condition @+10 ‐ +25° C.
Input Characteristics
Connection
Gain Setting
Analog Sends
1‐8*4
0
Analog
Returns 1‐8
n/a
Digital sends
& Returns 1‐8
AES3 Digital
(Mixer End)
*1–Hum & Noise are measured with an AES17 compliant filter at 20 kHz. Temperature condition @+10 ‐ +25° C. *2–0dBu is referenced to 0.775Vrms. *3–Sensitivity is the lowest level that will produce an
output of +4dBu (1.23V).
Output Characteristics
Connection
Analog Returns 1‐8 (Stage)
Box)*1
Analog Sends 1‐8 (Mixer)
End)
Digital Sends & Returns 1‐8
*1–All XLR connectors are balanced. *2–0 dBu is referenced to 0.775 Vrms.
Optical Characteristics
Connector*1
Installation Tension
Voltage Gain*2
Sensitivity*3
0(0 dB)
1.65 Vrms
0(0 dB)
1.65 mVrms
Actual Source
For Use With Nominal
Impedance
150
600 Lines
150
600 Lines
AES3 Digital
Operating Tension
• Analog line level OR AES digital input
• Simultaneous analog / AES3 digital outputs
• Heavy gauge steel construction
• Extended range and flexibility means limitless routing options
1 KHz @ +4 dBu
20‐20kHz @ +16 dBu
0.473 mA @ 90V
1 Rack Unit X 6.5" Deep
6.5 lbs
6 lbs
S/N ref +0dBu
Overload
‐83 dBu
+16 dBu
‐83 dBu
+16 dBu
Output Level*2
Nominal Max
Before Clip
+4 dBu (1.23
+19 dBu (7 V)
V)
+4 dBu (1.23
+19 dBu (7 V)
V)
Min Bend Radius
Crush Resistance
Clipping
Input Impedance
1.8 K
XLR
+19 dBu
10 K
TRS
2 K
+19 dBu
Connector*1
DB‐25, Tascam™ DA‐88 pinout, 8
DB‐25, Tascam™ DA‐88 pinout, 8
channels per connector
DB‐25, 8 channels per connector
Weight