Indicators and Controls 
1
The VIM‐1808 and VIM‐0808 are identical with 2 exceptions – the VIM‐1808 contains the native system clock and an external clock input, and the VIM‐0808 
does not. Therefore, only the VIM‐1808 is pictured in this document
1
 Analog Outputs 
The (8) analog line level outputs on the VIM‐1808 are 
connected via (1) DB25 connectors, (8) channels per DB25 
connector. 
 Analog Inputs 
2
The (8) inputs are connected via a single DB25 connector. 
Inputs are line level. 
3
 Input Selection Switch 
 Digital Inputs 
4
The (8) digital returns are connected via a single DB25 
connector. Digital inputs are all AES3 compliant. 
 Digital Outputs 
5
The (8) AES digital outputs on the VIM‐1832 are connected 
via (1) DB25 connectors, (8) channels per DB25 connector. 
6
 Primary Fiber Connection 
The VIM‐1808 contains a single primary pair of fiber 
connectors. Always be certain to use appropriate fiber and 
connectors. LightViper systems use multimode fiber. Single 
mode optics are available on a custom basis for situations 
where single mode fiber may already exist. 
7
 Fiber Thru Connection 
 
8
 Control Circuit Connector 
This RJ45 connector provides (3) bi‐directional CMOS or TTL 
data lines (up to 38.4KHz from VIM‐0808 to VIM‐1808 and 
2MHz from VIM‐1808 to VIM‐0808) plus voltage and GND. 
This connector is used in conjunction with DGL‐422 cables 
for transporting Yamaha control, or with MD3 units to 
transport RS‐422, RS‐232 or MIDI. THIS IS NOT AN ETHERNET 
CONNECTOR – CONNECTING AN ETHERNET DEVICE TO THIS 
CONNECTOR COULD DAMAGE THE DEVICE. The pin outs for 
this connector are detailed in the appendix. Most CMOS or 
TTL functions / equipment can be adapted to make use of 
this connector. 
9
 Sync LED 
This LED indicates the status of the fiber‐optic link between 
the VIM‐1808 and VIM‐0808. It has three states; SOLID RED 
indicates there is no sync present; ALTERNATING RED & 
GREEN indicates the unit is searching for sync; SOLID GREEN 
indicates sync is present (optical link) and OFF indicates no 
power. 
 Power Connector / Fuse 
10
The AC power connection to the VIM‐1808 & VIM‐0808 are 
made via the supplied IEC power cords. The internal power 
11
13
12
2
3
6
4
5
supply can accept 90‐260V at either 50 or 60 Hz> The power 
fuse is a 5x20mm, 1A Slo‐Blo. Only replace the fuse with an 
exact match. If after replacement the fuse blows again, 
contact Fiberplex for service. 
 Word Clock External Input 
11
 Clock Frequency Switch 
12
chooses between analog line level and digital returns 
 Word Clock  / Super Clock Output 
13
7
8
9
10
 