AC output data PV Point
Nominal frequency
Switchover time
Power factor cos phi
General data
Maximum efficiency
European efficiency (U
European efficiency (U
European efficiency (U
Self-consumption at night
Cooling
Protection class
Dimensions H x W x D
Weight
Inverter topology
Permitted ambient temperature
Permissible humidity
EMC device class
DC/AC overvoltage category
(in accordance with IEC 62109-1)
Pollution degree
Sound pressure
Safety class (according to IEC62103)
Protection devices
DC isolation measurement
Overload performance
DC disconnector
RCMU
RCMU classification
Active anti-islanding method
Power per digital output
(for external supply)
Datalogger/web server
146
2)
)
mpp nom
)
mpp max
)
mpp min
The software class of the safety plat-
trol function (single channel with peri-
odic self-test) according to IEC60730
Controlled forced-air ventilation
530 x 474 x 165 mm
Non-insulated transformerless
-25 °C – +60 °C
0–100% (incl. condensation)
Warning / shutdown at R
Operating point shift, power limiter
form(s) is specified as a class B con-
Frequency conversion method
1 A at >12.5 V-24 V
(max. 3 A in total)
1)
53 / 63 Hz
< 90 s
0 - 1
98.1%
96.7%
96%
95.1%
< 10 W
IP 66
16.5 kg
B
2/3
2
36 dB(A)
1
<
ISO
100 kOHM
Integrated
Integrated
Annex H.
Integrated