Regardless of when or by whom your vessel may have been installed, there are a few quick checks you should
make before use. Check that each vessel is:
Mounted with compliant material (Polyurethane saddle) between the fiberglass shell and any rigid frame.
Free to expand under pressure - shell not clamped rigidly in place, no rigid piping connections to port fittings.
Not used in any way to support other components such as piping, manifolds hanging from ports.
Section through end closure
Dwg Ref
Qty Per
1
1
2
2
3
2
4
2
5
2
6*
2
7*
2
8*
4
Not shown in above cross section
Item #
Description
Shell
95927
End Plug
45317
Plug Seal
45296
Adapter Seal
Head Interlock
45260
Retaining Ring
Vessel Support - Optional
45058
Saddle
47459
Strap Assembly
97821
Strap Screw
Materials
Shell
Filament Wound epoxy/ glass composite. Head
locking grooves internally wound in place. Shell
exterior coated with Blue high gloss polyurethane
paint.
Head
Engg. Thermoplastic
Ethylene Polypropylene-O-ring
Ethylene Propylene O-ring
316L Stainless steel
Engg. Thermoplastic
304 SST – PVC Cushion
5/ 16 UNC, 18-8 Stainless Steel