Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion-controls.com
MODEL PSDR7 - SIGNAL CONDITIONER 1 A POWER SUPPLY
SPECIFICATIONS
1. POWER REQUIREMENTS:
Input Voltage Nominal: 100 to 240 VAC
Input Voltage Range: 85 to 264 VAC or 90 to 350 VDC
Current Consumption at nominal input voltage: 0.22/0.45 A (230/120 VAC)
2. FREQUENCY: 45 to 65 Hz
3. INRUSH CURRENT LIMITATION: I
4. RECOMMENDED BACKUP FUSE:
power circuit breaker: 6A / 10 A
Characteristic: B
5. MAINS BUFFERING: >20 msec (120 VAC); >110 msec (230 VAC)
6. SURGE VOLTAGE PROTECTION: Varistor
7. POWER OUTPUT: Adjustable from 22.5 to 28.5 VDC @ 1 A via
potentiometer
8. EFFICIENCY: > 80 % at 230 VAC nominal values
9. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range: -25 to 70°C (>+60°C derating)
Storage Temperature: -40 to 85°C
Humidity, no moisture condensation: 95 % at 25°C
Vibration in acc. with IEC 68-2-6: <15 Hz, amplitude ±2.5 mm;
15 Hz - 150 Hz, 2.3 g
Shock in all directions acc. with IEC 68-2-27: 30 g
Contamination in acc. with EN 50178: 2
10. STANDARDS AND CERTIFICATIONS:
Electrical equipment of machines
(surge voltage category III)
Electrical Safety
Electronic equipment for use in
electrical power installations
Limitation of output power
Safe isolation
DIMENSIONS In inches (mm)
2
t (+25 °C) typ: <15 A / < 0.6 A
EN 60 204
EN 60950 / VDE 0805
UL 508 listed
EN 60950 / VDE 0805
UL Recognized UL 60 950
EN 50178 / VDE 0160
NEC Class 2
VDE 0100-410
DIN VDE 0106-101
DESCRIPTION
The compact PSDR power supplies are industrial input voltage supplies with
primary switched-mode regulator technology. They feature low output ripple
and adjusted output voltage from 22.5 to 28.5 VDC. The output is electronically
protected against overloads and short circuits.
The modules snap onto standard 35 mm flat DIN rails and use removable
terminal blocks for easy wiring.
In conformance with EMC guideline 89/336/EEC
and low-voltage directive 73/23/EEC
EMC (Electromagnetic compatibility)
Immunity in accordance with EN 61000-6-2
Discharge of static electricity (ESD)
2
s
Electromagnetic HF field
Fast transients (Burst)
Surge voltage capacities (Surge)
Conducted disturbance
Voltage dips
Simulation mobile phones
Noise emission according to EN 50081-2
Emitted radio interference
Radio interference voltage
EN 55011 corresponds to CISPR11 / EN 55022 corresponds to CISPR22
EN 61000 corresponds to IEC 1000
1)
Normal operating behavior within the defined limits.
Criterion A:
Temporary impairment to operational behavior, that is
2)
Criterion B:
corrected by the device itself.
3)
Conductor to conductor.
Symmetrical:
4)
Asymmetrical: Conductor to ground.
5)
Area of application industry and residential.
Class B:
11. ISOLATION VOLTAGE: Input/Output 3 kV
12. INSTALLATION POSITION: On horizontal mounting rail according to
EN 50022-35
13. CONNECTIONS: 24 to 14 AWG max. Torque 4.5 to 5.3 inch-lbs.
14. MOUNTING: Standard DIN rail top hat (T) profile rail according to
EN50022 - 35 X 7.5 and 35 X 15. Can be mounted in rows with vertical
Spacing > 5 cm or horizontally with no space.
15. CONSTRUCTION: Case body is green, high impact plastic. IP20 touch
safe. Protection Class II.
16. MTBF (Mean Time Between Failure): >500000 h acc. To IEC 1709 (SN 29500)
17. WEIGHT: 7.4 oz (209 g)
Bulletin No. PSDR7-X
Drawing No. LP0576
Effective 11/03
2)
Housing > Level 3
EN 61000-4-2
Contact discharge: 8 kV
Discharge in air: 8 kV
1)
Housing Level 3
EN 61000-4-3
Frequency/Field intensity: 80-1000
MHz / 1.4-2.0 GHz / 10 V/m
2)
4)
EN 61000-4-4
Input: 4 kV (Level 4)
Signal: 1 kV (Level 2)
2)
4)
4)
EN 61000-4-5
Input: 4 kV
/ 2 kV
Level 4)
4)
Output: 0.5 kV
/ 0.5 kV
4)
Signal: 0.5 kV
(Level 1)
1)
I/O/S: Level 3
EN 61000-4-6
Frequency/U
: 0.15-80 MHz / 10 V
o
2)
Input: see mains buffering
EN 61000-4-11
> 20 ms
EN 50204
Frequency: 900 MHz, 1800 MHz
Field intensity: 20 V/m
EN 55011 (EN 55022) Class B
EN 55011 (EN 55022) Class B
4)
4)
(Inst Class 4 /
3)
(Level 1)
5)
5)
Need help?
Do you have a question about the PSDR7 and is the answer not in the manual?
Questions and answers