Intended Use; Introduction; Initial Use; How The Infrared Lamp Helps - Silvercrest SRL 100 A1 Operating Manual

Hide thumbs Also See for SRL 100 A1:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 33
1) Use the infrared emitter only
i
with a Philips R95 E27,
230 V, 100 W infrared bulb.
Do not use any other bulb and
if any bulb is purchased
subsequently, ensure that it is
identical with the version
supplied here.
2) Do not place any flammable
objects in the area of
irradiation: combs, spectacle
frames etc. can catch fire and
textiles may be singed.
3) Avoid sudden cooling
IR111_LB5.book Page 32 Thursday, August 5, 2010 2:27 PM
(e.g. of the head) immediately
after treatment.
4) Protect the lamp from strong
impacts, including setting
down harshly.
Do not place the appliance
5) Remember not to put the
on hot surfaces or near to
appliance away immediately
heat sources and lay the
Caution
after switching it off, but allow it
mains cable in such a way
to cool first for a few minutes.
that it does not come into
6) Disconnection from the
contact with hot or sharp-
mains supply is only
edged objects.
guaranteed if the plug is
Do not use the appliance
removed from the socket.
whilst standing on a wet
floor or if your hands or the
appliance are wet.

Intended Use

Do not bend the mains cable
and do not wind it around
The appliance may only be employed for its
the appliance.
intended use – for heat therapy and treating
Do not leave the appliance
illnesses. The infrared lamp is designed
unattended during
solely for use in private households and is
operation. Use only proper
not intended for commercial use. Any other
extension leads. Do not
use or modification to the appliance does
operate the appliance
not constitute an intended use and is
outdoors, as this may bring
fundamentally forbidden. No liability can be
it into contact with rain or
assumed for damage caused by use for
other moisture.
purposes other than the intended use or in
the event of improper operation.
Repairs are to be carried out

Introduction

i
only by authorised customer
service personnel. Never
It is a long-known fact that heat can relieve
attempt to open the appliance
pain and in many cases accelerate healing.
or e.g. to get into the inside
using metal objects.
34
GB
MT
Operating Instructions SRL 100 A1-51/2012-1.04
This healing heat is provided particularly
effectively by the infrared lamp, from which
the infrared radiation penetrates through
the skin and deep into the tissue beneath.
There is increased perfusion of the blood in
the area, the blood vessels expand, more
body-builders are taken to the irradiated
point and the body breaks down the more
"roughage". The recovery process can be
accelerated by the healing heat from the
infrared lamp.

Initial Use

Place the appliance on a level surface and
insert the mains plug into a properly
installed plug socket. The infrared lamp will
be illuminated.
Irradiation Distance
If the appliance is not used
i
properly or if it is operated
The distance should be such
incorrectly, no liability can
that the heat is felt to be com-
Danger
be accepted for any damage
fortable. Generally, the mini-
which occurs as a result.
mum clearance to 100 Watt
Persons (including children)
appliances is 60 cm.
who are unable to operate
Irradiation Duration
the appliance correctly due
The best results are achieved
to their physical, sensory or
with a treatment of 2 x 15 minu-
mental capabilities or lack of
tes per day.
experience or knowledge
should not use this
appliance without
How the Infrared Lamp
supervision or instruction by
Helps
a responsible person.
Rheumatism, muscle pain and lumbago
Electrical appliances are not
– Continue the daily treatment until no more
children's toys! Therefore,
pain is felt. In the case of articular
use and store the appliance
rheumatism, seek the advice of your
out of the reach of children.
doctor.
Do not allow the mains cable
to hang down.
Colds – The start of a cold can be
suppressed. If you already have a cold,
repeated treatment can provide significant
If the mains cable is damaged,
i
relief. However, only genuine colds should
it must be replaced only by a
be treated. In the case of maxillary sinus,
repair workshop nominated by
frontal sinus and throat infections,
the manufacturer (see
treatment should only be undertaken
guarantee card), in order to
avoid any danger.
This appliance is designed
solely for use in private
37
GB
MT

Advertisement

Table of Contents
loading

This manual is also suitable for:

78366

Table of Contents