Omron ZJ-FA10V Series Instruction Sheet page 4

Advanced fan type ionizer

Advertisement

Parts Names and Functions
Front End
(5)  (2)  (1)  (4)  (3) (6)
(7)
(8)
(1) Indicator
Indicates charged status on an object/ion balance/fan speed based on
selection by mode selection switch and indicator status selection
switch.
(2) Power lamp
The green lamp turns ON when the power is ON.
(3) Cleaning notice/alarm lamp
The lamp turns orange as notification when discharge needles get dirty
and neutralization performance is degraded.
The lamp turns red when the product no longer works.
(4) Error lamp
Turns red when an error occurs.
(5) Mode selection switch
Switches modes.
RUN mode: Select this if you want to see charged status on an object or
ion balance.
Balance adjustment mode: Select this if you want to adjust ion balance.
Fan speed adjustment mode: Select this if you want to see or adjust fan
speed.
(6) Indicator status selection switch
Selects indication under RUN mode.
Selection is available from charged status (built-in sensor)/charged
status (external static electricity sensor)/ion balance.
(7) Adjuster keys
Adjusts fan speed and ion balance.
(8) Sensor electrode
Detects charged status of an object and ion balance blown off from the
ionizer.
Back End
(1) Power input selection switch
Selects a power input from the AC adapter or input/output connector.
(2) AC adapter connector
Provides connection to the AC adapter.
(3) Ground terminal
Always earth this terminal.
(4) Input/output connector
Accessory input output cable can be connected to this for power input,
cleaning output, abnormal discharge output, and charged status output.
(5) Static electricity sensor connector
Provides connection with the statis electricity sensor head ZJ-SD100
(option).
(6) Air filter
Prevents dirt from entering the unit.
How to Use Mounting Bracket
1. Name of Parts
Holding knob (X2)
Angle adjuster washer
(X2)
Holder
Mounting hole 5-5.5 dia.
Rubber pad (X4)
2. Mounting and Operation
On desktop
(1) Untighten the holding knob and adjust an angle of the ionizer unit as
you wish.
(2) Tighten the knob and screws after adjusting the angle.
Attaching directly to a device
(1) Remove the 4 rubber pads (4).
(2) Mount the unit using mounting holes of the holder. Use M5 screws
and tighten them with tightening torque of 2.3 to 2.8Nm.
Attching to a pipe (dia. 28) (optional ZJ9-FA-BR01 required)
(1) Insert angle adjuster washers to the holder.
(2) Use accessory M6 screws to fix the base, plate, and pipe-mounting
bracket.
(3) Adjust the angle and tighten the holding knob.
 
Holding knob
Base
Holder
Angle adjuster
washer
Pipe-mounting
M6 screw (x 2)
bracket
Plate
Pipe
Dia. 28
 
 
Function
High voltage circuit failure detection
- Details
Detects a failure in a high voltage circuit, displays warning, and stops the
operation.
Status when abnormal discharge is detected
ZJ-FA10V(-D)
ZJ-FA10V-(D)1
Fan
Stop
Display
Power lamp
ON
Error lamp
ON
Cleaning lamp
OFF
Indicator
OFF
Output
Cleaning output
ON
Error output
OFF
- Recovery condition
Recovery from abnormal discharge mode requires turning the power off
and on again.
If recovery failed, contact Omron's sales person in charge.
Emergency stop
- Outline
Fan and high voltage circuit stop when the access panel is opened or the
air filter case is removed.
Access panel
Status at emergency stop
ZJ-FA10V(-D)
Fan
Display
Power lamp
Error lamp
Cleaning lamp
Indicator
Output
Cleaning output
Error output
- Recovery condition
Recovery from abnormal discharge mode requires turning the power off
and the access panel must be closed and the air filter case must be
attached. Then the power needs to be ON
Recovery to a normal status cannot be executed even if the access panel
is closed and the air filter case is attached while the power is ON.
Cleaning indication
The cleaning notice lamp turns ON when discharge needles get dirty and
neutralization performance is degraded.
* Indication (1): Cleaning notice lamp (Orange)
When ion balance may not be maintained or deionizing
performance may be degraded unless cleaned
Indication (2): Cleaning alarm lamp (Red)
When ion balance or deionizing performance cannot be
maintained
It takes about 20 seconds from power on to turning on of the alarm lamp.
 
External Dimensions
OFF
ON
When optional bracket ZJ9-FA-BR02 is used
Air filter case
ZJ-FA10V-(D)1
Stop
Blink
ON
OFF
OFF
ON
OFF
OFF
ON