Omron R87FT Datasheet

Ac axial-flow fans

Advertisement

Quick Links

AC Axial-flow Fans
R87F/R87T
Optimum Cooling with a Comprehensive
Lineup of Axial-flow Fans
• Low noise level, long service life, and resistance to the environ-
ment.
• Shaft supported by ball bearings for highly-reliable operation.
• Plastic-bladed models (48 type) and metal-bladed models (24
type) included in series.
• R87F-A@A16H-WR Water-resistant AC Axial-flow Fans (IP65
degree of protection) added to series.
• A wide range of models with CSA, VDE, and EN/IEC approval
also available.
Model Number Structure
■ Model Number Legend
R87
-
1
2
3
4
5
1. Basic series
R87F:
Plastic blade
R87T:
Metal blade
2. Rated voltage
A1:
100 VAC
A3:
115 VAC
A4:
200 VAC
A6:
230 VAC
3. Frame material
A: Die-cast aluminum
Note: 1. A Plug Cord (R87F-PC) is available as an option for models with terminals.
2. These tables show only how to read product markings. They do not indicate which products are available. Refer to product ratings when
ordering.
Ordering Information
■ Available Models
AC Axial-flow Fans
Series
Size (mm)
R87F
120 120 t40
R87F-A@A16H-WR
(plastic
120 120 t38
R87F-A@A15
blades)
120 120 t25
R87F-A@A13
92 92 t25
R87F-A@A93
80 80 t38
R87F-A@A85
80 80 t25
R87F-A@A83
R87T
150-dia. t55
R87T-A@A07
(metal
150-dia. t38
R87T-A@A05
blades)
120 120 t38
R87T-A@A15
80 80 t38
R87T-A@A85
80 80 t25
R87T-A@A83
Note: Mounting screws are not provided.
-
6
7
8
4. Frame size
0:
150 dia.
1:
120×120
9:
92×92
8:
80×80
5. Frame thickness
3:
25
5:
38
6:
40
7:
55
Model
Page number
Refer to page 19.
Refer to page 21.
Refer to page 23.
Refer to page 25.
Refer to page 27.
Refer to page 29.
Refer to page 31.
Refer to page 33.
Refer to page 35.
Refer to page 37.
Refer to page 39.
6. Rotational speed
H: High
M: Medium
L:
Low
7. Terminal type
No marking: Lead wires
P:
Terminals (See note 1.)
8. Type
No marking: Standard
WR:
Water-resistant
Options
Product name
Model
Plug Cord
R87F-PC
Finger Guard
R87F-FG@
Filter
R87F-FL@(S)
AC Axial-flow Fans
Page number
Refer to page 41.
Refer to page 41.
Refer to page 42.
R87F/R87T
M-15

Advertisement

Table of Contents
loading

Summary of Contents for Omron R87FT

  • Page 1 A: Die-cast aluminum Note: 1. A Plug Cord (R87F-PC) is available as an option for models with terminals. 2. These tables show only how to read product markings. They do not indicate which products are available. Refer to product ratings when ordering.
  • Page 2 R87F/R87T M-16 AC Axial-flow Fans...
  • Page 3 R87F-A4A83L 200 VAC R87F-A6A83L 230 VAC Note: The products approved by standard organizations satisfied the following tests. UL approval number: UL507 (UL519, UL547) CSA approval number: C22.2 (No. 0, No. 113) VDE approval number: DIN/EN60950 (VDE0805), EN60950, IEC950 TÜV approval number: VDE0700 Teil 1, VDE0700 Teil 234, EN60355-1, IEC335-1...
  • Page 4: Selection Guide

    R87F-FL@ Refer to page 42. R87F-FL@S Note: The products approved by standard organizations satisfied the following tests. UL approval number: UL507 (UL519, UL547) CSA approval number: C22.2 (No. 0, No. 113) VDE approval number: DIN/EN60950 (VDE0805), EN60950, IEC950 TÜV approval number: VDE0700 Teil 1, VDE0700 Teil 234, EN60355-1, IEC335-1...
  • Page 5 Note: Other applications include discharging air in outdoor devices (small-size outdoor devices), and cooling internal components of machine tools and switchboards in industrial devices. R87F-A@A16H-WR M-19 ntlp...
  • Page 6: Specifications

    Flow rate Q (m /min) tion IEC60529) and Material Safety Law, UL/ Note: For details on measurement condi- CSA, and IEC60335 tions, refer to “Flow Rate and Static Pressure” on page 45. Dimensions 39.8 119.5 17.8 Ground Screw Section Four M4 screws (See note.)
  • Page 7 (A)* speed /min)* (Pa)* range (%) (r/min)* 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz R87F-A1A15HP 85 to 110% 50/60 0.232 0.210 2700 3000 88.3...
  • Page 8 /min) Flow rate: Q (m /min) Flow rate: Q (m /min) Note: For details on measurement conditions, refer to “Flow Rate and Static Pressure” on page 45. Dimensions Four, 4.3 dia. Screw hole for grounding M4 screw: 0.7 pitch Terminal shape...
  • Page 9 (A)* speed /min)* (Pa)* range (%) (r/min)* 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz R87F-A1A13HP 85 to 110% 50/60 0.170 0.145 2500 2850 2.0 52.0...
  • Page 10 R87F-A@A13HP Flow rate: Q (m /min) Flow rate: Q (m /min) Note: For details on measurement conditions, refer to “Flow Rate and Static Pressure” on page 45. Dimensions Screw hole for grounding M4 screw: 0.7 pitch Terminal shape Faston #110 terminal (or equivalent) Panel Cut-outs For reference purposes.
  • Page 11 (A)* speed /min)* (Pa)* range (%) (r/min)* 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz R87F-A1A93HP 85 to 110% 50/60 0.130 0.110 2600 3050 1.0 46.1...
  • Page 12 R87F-A@A93LP Flow rate: Q (m /min) Flow rate: Q (m /min) Note: For details on measurement conditions, refer to “Flow Rate and Static Pressure” on page 45. Dimensions Three, 4.3 dia. Screw hole for grounding Direction of rotation M4 screw: 0.7 pitch...
  • Page 13 (A)* speed /min)* (Pa)* range (%) (r/min)* 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz R87F-A1A85HP 85 to 110% 50/60 0.121 0.111 2800 3250 0.66 0.76...
  • Page 14 R87F-A@A85LP Flow rate: Q (m /min) Flow rate: Q (m /min) Note: For details on measurement conditions, refer to “Flow Rate and Static Pressure” on page 45. Dimensions Four, 4.3 dia. Screw hole for grounding Direction of rotation M4 screw: 0.7 pitch...
  • Page 15 (A)* speed /min)* (Pa)* range (%) (r/min)* 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz R87F-A1A83H 85 to 110% rat- 50/60 0.091 0.080 2600 3000 0.57...
  • Page 16 R87F-A@A83L Flow rate: Q (m /min) Flow rate: Q (m /min) Note: For details on measurement conditions, refer to “Flow Rate and Static Pressure” on page 45. Dimensions Direction of flow Screw hole for grounding Side with label (front) M4 screw: 0.7 pitch...
  • Page 17 (A)* speed /min)* (Pa)* range (%) (r/min)* 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz R87T-A1A07H 85 to 110% rat- 50/60 0.660 0.560 2750 3050 5.0 111.7 127.5 55...
  • Page 18 ■ Flow Rate and Static Pressure Characteristics (Reference Value) R87T-A@A07H Flow rate: Q (m /min) Note: For details on measurement conditions, refer to “Flow Rate and Static Pressure” on page 45. Dimensions Screw hole for grounding Two, 4.3 dia. 150 dia.
  • Page 19 (A)* speed /min)* (Pa)* range (%) (r/min)* 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz R87T-A1A05H 85 to 110% rat- 50/60 0.540 0.470 2600 2950 5.2 98.1...
  • Page 20 ■ Flow Rate and Static Pressure Characteristics (Reference Value) R87T-A@A05H Flow rate: Q (m /min) Note: For details on measurement conditions, refer to “Flow Rate and Static Pressure” on page 45. Dimensions Screw hole for grounding Two, 4.3 dia. Direction of rotation 150 dia.
  • Page 21 (A)* speed /min)* (Pa)* range (%) (r/min)* 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz R87T-A1A15HP 85 to 110% 50/60 0.230 0.210 2700 3050 2.5 68.6...
  • Page 22 R87T-A@A15HP Flow rate: Q (m /min) Flow rate: Q (m /min) Note: For details on measurement conditions, refer to “Flow Rate and Static Pressure” on page 45. Dimensions Four, 4.3 dia. Screw hole for grounding M4 screw: 0.7 pitch Terminal shape...
  • Page 23 (A)* speed /min)* (Pa)* range (%) (r/min)* 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz R87T-A1A85H 85 to 110% rat- 50/60 0.170 0.150 2700 3150 0.73...
  • Page 24 ■ Flow Rate and Static Pressure Characteristics (Reference Value) R87T-A@A85H Flow rate: Q (m /min) Note: For details on measurement conditions, refer to “Flow Rate and Static Pressure” on page 45. Dimensions Screw hole for grounding Direction of flow Screw hole for grounding...
  • Page 25 AC Axial-flow Fans with Lead Wires (80 x 80 x t25 mm) R87T-A@A83 Specifications ■ Ratings Note: * indicates a nominal value. Model Rated Permitted Frequency Rated current Rated input Rated rotational Maximum flow Max. static Noise (dB)* voltage voltage...
  • Page 26 Options Name Model Page number Finger Guard R87F-FG80 Refer to page 41. Filter R87F-FL80 Refer to page 42. R87T-A@A83 M-40 AC Axial-flow Fans with Lead Wires (80 x 80 x t25 mm)
  • Page 27 R87F-A@A1 Series R87F-FG120 92 92 R87F-FG90 R87T-A@A1 Series 80 80 R87F-FG80 92 92 R87F-A@A9 Series R87F-FG90 80 80 R87F-A@A8 Series R87F-FG80 R87T-A@A8 Series Note: Finger Guards reduce the flow rate by approximately 2% to 5%. Common Information M-41 AC Axial-flow Fans...
  • Page 28: Available Models

    R87T-A@A1 Series 120 120 R87F-FL120 92 92 R87F-A@A9 Series R87F-FL90 80 80 R87F-A@A8 Series R87F-FL80 R87T-A@A8 Series Note: Filters reduce the flow rate by approximately 20% to 40%. Ensure that there is no clogging. Common Information M-42 AC Axial-flow Fans...
  • Page 29: Application Examples

    Application Examples 1. Control Panels 4. Medical Equipment 2. Computer 5. Soldering Fume Extractor 3. Measurement Devices 6. Automatic Vending Machines and Display Cases Common Information M-43 AC Axial-flow Fans...
  • Page 30: Correct Use

    Fan will be adversely affected. Leakage Flux Distribution Curves The leakage flux distribution curves for inlet and outlet sides of the R87T Axial-flow Fans are shown below as examples. Inlet Outlet...
  • Page 31 When installing the Fan, keep the clearance at the outlet side as A Fan installed in equipment operates near the point where the Fan small as possible. (If there is a large clearance at the outlet side, it characteristic curve crosses the system impedance curve.
  • Page 32: Noise Measurements

    OMRON conducts testing according to JIS (Japan Industrial Stan- or from previous data. dard) C 9603 because of the small size and low noise levels of the P = KQ Fans and because of their similarity in shape to extractor fans. This...
  • Page 33 Q2, for rately for details on rated values. example. This result indicates that the system impedance was so the Fan one size larger is necessary to produce the flow rate Q Flow Rate: Q (m /min.) The volume of air discharged by the Fan in a unit of time.
  • Page 34: Warranty

    CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE...

This manual is also suitable for:

R87t

Table of Contents