1
Room temperature calibration: Calibrate the
temperature detected by the room sensor.
2
Floor temperature calibration: Calibrate the
temperature detected by the floor sensor.
3&4
Anti-freeze function: This option is ideal for
warming plants and pets with a lower temperature.
displays when the thermostat is switched off.
*It can also protect the pipework from freezing when
using a water heating system.
5
Floor temperature limit: If both sensors are chosen,
the maximum floor temperature value can be set and
the system will stop heating if the floor temperature
exceeds this value.
6
Temperature tolerance: Default value is 1°C. The
thermostat starts when the room temperature is 1°C
lower than set temperature and stops when the room
temperature is 1°C higher than set temperature.
7
Temperature unit: °C and °F can be selected.
8
Sensor selection:
Room sensor:
Run by room sensor
Floor sensor:
Run by floor sensor
Both sensors:
Run by room sensor with floor
temperature limit
9
Schedule: Select a weekly schedule for the Edit
Setting. There are 2 options:
7: Each weekday from Monday to Sunday can be set
individually.
5+1+1: Weekdays, Monday to Friday have the same
events; Saturday & Sunday can be set individually.
10
Output delay: This option helps avoid inadvertent
operation on heating.
11
Adaptive function: After several days of installation
and use, the adaptive function learns that the
required temperature has already been reached
when the next event begins.
12
Open window: This function only works when in
Room Sensor or Both Sensors mode. When a window
is opened, this function detects the sudden change
in room temperature and automatically switches off
the thermostat for 15 minutes.
13&
Energy use: This option allows various data to be
14
entered and used to calculate energy use.
Continued overleaf