Lcd Display - Kohler 60RCLA Operation

Residential/light commercial generator sets
Hide thumbs Also See for 60RCLA:
Table of Contents

Advertisement

3.2.3

LCD Display

The controller is equipped with a two-line x 16 character
backlit liquid crystal diode (LCD) display with adjustable
contrast. When the generator is running, the controller
automatically scrolls through the displays shown in
Figure 3-4. When the system is in AUTO, the LCD
display scrolls through the status messages shown in
Figure 3-5.
When a fault or warning condition exists, the controller
will show the corresponding message. See Section 2.6
for more information on fault and warning messages.
Controller menus display power system information,
including status information for the engine, generator,
and optional RBUS accessories, exercise settings, and
event history.
Some menus allow changes to the
controller settings. See Sections 3.6 through 3.19 for
menu diagrams.
Active Alert
Genset Status
Running
Voltage: 240V
Freq:
Engine:
Oil Pressure: 40 psi
Battery
Engine Runtime:
Date:
Time:
Figure 3-4 Autopaging Displays, Generator Running
TP-7102 4/18
60.0Hz
123F
12.3V
27.4 h
02Jan2018
HR:MNpm
Sample data shown.
The display contrast is adjustable. Navigate to the
Genset System menu and step down to the Contrast
screen. Press the Select button, and then use the up
and down arrow buttons to adjust the contrast. See
Section 3.5, Changing Settings, and Section 3.11,
Generator Set System Menu.
The display backlight turns off after about a minute of no
activity. The backlight turns on when a button is pressed
or when the generator set starts.
Figure 3-5 Autopaging Displays, Automatic Mode
tp6810
Genset Status
Standby
Battery
12.3V
Engine Runtime:
27.4 h
Date:
02Jan2018
Time:
HR:MNpm
Next Exercise:
09:00p 09Jan2018
Next Maintenance:
150 h or Jan2019
SW Version:
1.01
Sample data shown.
Section 3 RDC2 Controller Operation
tp7102
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

48rclbRdc248rclc-qs1

Table of Contents