Advertisement

Quick Links

GEC
5.0-9.6kW G1(US)
Split Phase
Quick Installation Guide
Ver.1.2
AC-Coupled Inverter
www.gesolarinverter.com

Advertisement

Table of Contents
loading

Summary of Contents for GE GEC 5.0kW G1 Split Phase

  • Page 1 5.0-9.6kW G1(US) Split Phase Quick Installation Guide Ver.1.2 AC-Coupled Inverter www.gesolarinverter.com...
  • Page 2: Safety Precautions

    Safety Precautions General Disclaimer • The information in this quick installation guide is subject to change due to product updates or other reasons. This guide cannot replace the product labels or the safety precautions in the user manual unless otherwise specified. All descriptions here are for guidance only. •...
  • Page 3: Check Before Power On

    Product Enclosure: 1. Do not apply mechanical load to the terminals, otherwise the terminals can be damaged. 2. All labels and warning marks should be visible after the installation. Do not scrawl, damage, or cover any label on the device. 3.
  • Page 4: Led Explanation

    LED Explanation Indicator Status Explanation ON = The system is ready. SYSTEM BLINK = The system is starting. OFF = The system is not working. ON = Back-up is ready / power available. BACK-UP OFF = Back-up is off / power not available. ON = The battery is charging.
  • Page 5: Product Introductions

    Product Introductions Parts BAT Input Terminal WiFi Reset - BAT INPUT Auto-transformer Terminal Backup Terminal On Grid Terminal - A-TX - BACK UP - GRID Meter CT Terminal LG Enable & 12V Power & PE Terminal WiFi Module Dry Contact...
  • Page 6 Dimensions 175mm 415mm 6.9in 16.3in 110mm 120mm 4.3in 4.7in 110mm 4.3in 120mm 4.7in 140mm 5.5in GEC Inverter 174mm 345mm 6.9in 13.6in 110mm 120mm 4.3in 4.7in 110mm 4.3in Auto Transformer...
  • Page 7: Inverter Installation

    Inverter Installation Packing List GEC Inverter x N* * means the number of actual accessories may differ depending on different model. Auto Transformer...
  • Page 8 Space Requirements -31°F~140°F NEMA (-35°C~60°C) 0%~95%RH 66lb 48.5lb (30kg) (22kg) ≥300mm ≥500mm 11.81in 19.69in ≥200mm ≥200mm ≥100mm ≥100mm 3.94in 3.94in 7.87in 7.87in ≥200mm ≥300mm 7.87in 11.81in ≥300mm ≥300mm 11.81in 11.81in Angle Requirements ≤15° ≤15°...
  • Page 9 Installing the Inverter Avoid the water pipes and cables buried in the wall when drilling holes. GEC Inverter Auto Transformer...
  • Page 10: Electrical Connection

    Electrical Connection Preparations Before Electrical Connections...
  • Page 11 Wiring System Wiring System for GEC-US Series Inverter (Full Load) Grid Power meter Meter CT Communication Automatic Transfer Switch On-grid Output Breaker Back-up Output Breaker Main Breaker Battery Load Power ON Turn on Power OFF Turn off Auto-transformer...
  • Page 12 Ground Bus-bar Neutral Bus-bar...
  • Page 13 Wiring System for GEC-US Series Inverter (Partial Load) Grid Power Meter Main Breaker Meter CT Communication AC Breaker AC Breaker Load Back-up Breaker Battery 120V 240V Loads Loads Auto-transformer Power ON Turn on Power OFF Turn off...
  • Page 14 Ground Bus-bar Neutral Bus-bar Neutral Bus-bar Ground Bus-bar...
  • Page 15 Battery Cable 18mm Φ: max 7.4mm (0.71in) (0.29in) 18mm Φ: max 7.4mm (0.71in) (0.29in) 18mm Φ: max 7.4mm (0.71in) (0.29in) 90℃ Copper, 6 AWG...
  • Page 16 AC Cable (On-Grid) 18mm Φ: max 7.4mm (0.71in) (0.29in) 18mm Φ: max 7.4mm (0.71in) (0.29in) 18mm Φ: max 7.4mm (0.71in) (0.29in) 90℃ Copper, 8-10 AWG...
  • Page 17 AC Cable (BACKUP) 18mm Φ: max 7.4mm (0.71in) (0.29in) 18mm Φ: max 7.4mm (0.71in) (0.29in) 18mm Φ: max 7.4mm (0.71in) (0.29in) 90℃ Copper, 8-10 AWG...
  • Page 18 CT Cable To CT Type One: CAN1 Battery (CAN1 Communication) BMS Cable: 22AWG, 600V Insulated CAN1...
  • Page 19 Type Two: LG Battery (485 Communication) LG Battery CAN_H LG_EN+ EN GND LG_EN- ENABLE_H 485-1A RS485_H 485-1B RS485_L CAN_L LG_EN+ LG_EN- LG_EN+ LG_EN-...
  • Page 20 Communication Module Auto-transformer (Optional) 18mm (0.71in) Φ: max 7.4mm L1/L2 (0.29in) 18mm (0.71in) Φ: max 7.4mm (0.29in) 18mm (0.71in) Φ: max 7.4mm (0.29in) 90°C Copper, 8-10 AWG 22-24 AWG, 600V insulated 7mm(0.28in) L1 N L2 PE...
  • Page 21: Commissioning And Monitoring

    05 Commissioning and Monitoring Commissioning via Storage Mate App play Storage Mate App Store <10m <5m Storage Mate APP Storage Mate APP Monitoring via Power Sight App play Power Sight App Store Power Sight APP For more detailed instructions, scan the QR codes below. GEC Series User Manual...
  • Page 22 Global Sales & Service Network * GE is a registered trademark of General Electric Company and is used under license by GoodWe Technologies Co., Ltd. © 2022 All Rights Reserved No. 90 Zijin Rd., New District, Suzhou, 215011, China www.gesolarinverter.com sales@gesolarinverter.com;...

This manual is also suitable for:

Gec 9.6kw g1 split phase

Table of Contents