Eickemeyer HIRAY 5 User Manual

X-ray machine
Hide thumbs Also See for HIRAY 5:

Advertisement

Quick Links

HIRAY 5
X - RAY MACHINE
USER MANUAL
Item no. 701105
TELEPHONE +49 7461 96 580 0
www.eickemeyer.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HIRAY 5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eickemeyer HIRAY 5

  • Page 1 HIRAY 5 X - RAY MACHINE USER MANUAL Item no. 701105 TELEPHONE +49 7461 96 580 0 www.eickemeyer.com...
  • Page 2 USER MANUAL HIRAY 5 X - RAY MACHINE T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
  • Page 3: Table Of Contents

    Optimum Ambient Conditions ....................... 12 Dimensions (in cm) ..........................12 Net Weight ............................. 12 Included Accessory ..........................12 Power Source for HiRay 5 ...................... 13 T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
  • Page 4: Introduction

    1. INTRODUCTION HiRay 5 is the most advanced portable and high-power X-Ray unit available both for the fi eld and clinic application, which is 120 kV in tube voltage, and 5 kW in maximum output power. The built-in collimator with 2 crossing lines and 2 laser pointers confi...
  • Page 5 416 mm F FA 203 mm 260 mm Fig. 1 Fig. 2 22.5 mm 160 mm 15 mm 350 mm Fig. 3 Fig. 4 T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
  • Page 6 This lamp lights for waiting or error READY (Green) This lamp lights when ready for exposure X-RAY (Yellow) This lamp lights during exposure kV display mAs display T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
  • Page 7 Reset VD/DV LATERAL BABY NASAL SKULL C-SPINE T-SPINE L-SPINE PELVIS/ HIP JOINT SCALPULA LUNG ABDOMEN HUMERUS CARPUS FEMUR PHALANX TARSUS LAMP Fig. 5 T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
  • Page 8: The Apr Technique

    There are no factory settings in the APR memory. Please register a set of APR data for your application before you use the unit fi rst time. T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
  • Page 9: Operation

    6. After the exposure, the wait lamp lights and next exposure is ready when this lamp is extinguished. This wait lamp also works as the alarm lamp and the lamp is fl ickering continuously in case any issue occurs in the circuit. T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
  • Page 10 Do not place the laser pointer for direct eye exposure since the laser beam is dangerous to the eyes. Fig. 6 Fig. 7 T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
  • Page 11: Specifications

    • Power requirement: AC 200 – 240 V ± 10 % (50 / 60 Hz) • Input current: Max. 40 A (short-time rating) T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
  • Page 12: X-Ray Tube

    14 kg (only main unit) Included Accessory • Aluminium case • User Manual • Test data sheet • Hand switch • Power cord with fi lter T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
  • Page 13: Power Source For Hiray 5

    Operation of the HiRay 5 is not advised if other devices share the same circuit. Adequate power cannot be supplied to the HiRay 5 and can overload the circuit tripping breaker resulting in a decline in output power of the X-Ray and potential damage to the HiRay 5 and the other devices on the circuit.
  • Page 14 5 might malfunction even though it was installed correctly as in either Case A or Case B above. • When using wired connection as noted in Case B, after unplugging the HiRay 5 do not touch its electrode directly after unplugging it as there is a danger of electric shock.
  • Page 15 USER MANUAL HIRAY 5 X - RAY MACHINE NOTES T +49 7461 96 580 0 | F +49 7461 96 580 90 | export@eickemeyer.com | www.eickemeyer.com...
  • Page 16 GERMANY POLAND EICKEMEYER KG EICKEMEYER Sp. z o.o. Eltastraße 8 Al. Jana Pawła II 27 78532 Tuttlingen 00-867 Warszawa T +49 7461 96 580 0 T +48 22 185 55 76 F +49 7461 96 580 90 F +48 22 185 59 40 info@eickemeyer.de...