Download Print this page

LEGRAND Niloe 6 647 03 Quick Start Manual page 2

Energy saving switch

Advertisement

Niloé
TM
Energy saving switch
5. OPERATION
(continued)
 5.2 Two-way switch + energy saving switch
100 m max.
The IR sensor is activated when the light is switched on from one of the
two switches.
The energy saving switch opens the circuit after 10 minutes with no
movement detection.
6. INSTALLATION
Position
Height: 1.20 m
1,2 m
4 m
7. TECHNICAL FEATURES
 7.1 Protection class
Protection against mechanical impact: IK 02
Protection against solid bodies and liquids: IP 40 (assembled product) - IP 20 (without rocker plate)
 7.2 Material characteristics
Case: PC
Rocker plate: ABS
Support: PC charged 10% glass fiber
Halogen-free
UV resistance
Self-extinguishing:
+ 850°C / 30 s for insulating components holding in place live parts.
+ 650°C / 30 s for the other insulating components.
Technical data sheet: F02053EN/01
 5.3 Energy saving switch + energy saving switch
The IR sensor of the two switches are both activated when the light is
switched on.
The light will switch off when one of the two switches stays 10 minutes
with no movement detection.
8 m
Updated: 07/04/2016
Cat. No(s): 6 647 03 - 6 648 03
100 m max.
Detection angle: 120°
4 m
Created: 28/08/2015
8 m
2/3

Advertisement

loading

This manual is also suitable for:

Niloe 6 648 03