6-6
Table 6-4. Troubleshooting Table for Board and IC Signals (UHF2) (Continued)
IC Designator
Pin
Q601
E
B
C
1. All voltages are measured with a high-impedance digital voltmeter and expressed in volts DC relative to ground (0V).
2. Voltages are measured with a DC input voltage of 7.50 + .02 volts DC applied to the battery connector (J602).
3. All voltages are measured in the squelched receive mode, unless otherwise indicated.
4. Voltages are identical for VHF and UHF models unless otherwise indicated.
All manuals and user guides at all-guides.com
UHF2 Troubleshooting Tables: Troubleshooting Table for Board and IC Signals (UHF2)
Pin Function
GND
Audio_MUTE_CON
Mode
DC Voltage (V)
Comments (Condition)
0
Mute: Low
None Mute: High
Mute: High
None Mute: Low