Niigata seiki EOM133 Series Instruction Manual

Precision outside measuring instrument digital outside micrometer

Advertisement

Quick Links

PRECISION OUTSIDE MEASURING INSTRUMENT
DIGITAL OUTSIDE MICROMETER
Thank you for purchasing the Niigata Seiki DIGITAL OUTSIDE MICROMETER.
This precision gauge measures outside dimension of object placed between the Anvil and Spindle.
For safe and proper use of this product, please read this instruction manual before use and follow the procedures described.
Please keep manual where it is accessible to user for future reference.
Keep this manual with the instrument if transferred or leased to a third party.
For inquiries about this product, please contact dealer or Niigata Seiki at the address listed on the following page.
■PART
Meas. Surfaces
IDENTIFICATION
(Carbide Tips)
【REAR】
0-Point
Adj. Hole
Battery
Cover
5
0
ON/OFF
25
30
3
45
SET
40
Thermal
ABS
Shield
EOM133-125
EOM133-150
※ No Insulating Cover
SPECIFICATIONS
※ Not incl. quantization error (±1 count)
Meas. Range
Accuracy
Weight
Model No.
(mm)
( µm )
(g)
EOM133-25
0− 25
265
4
EOM133-50
25− 50
380
EOM133-75
50− 75
460
EOM133-100
75−100
600
6
EOM133-125
100−125
515
EOM133-150
125−150
560
Resolution: 0.001mm
Power: SR44 (Silver Oxide Battery)
TROUBLESHOOTING
ERROR
CORRECTIVE ACTION
Measured value is
Clean measuring surfaces
wrong.
with cloth.
Confirm 0-Point setting and
re-zero with long press of
[SET] Button (> 2 sec.)
Cycle power by removing
LCD does not display.
and replacing battery.
Displayed value is
Replace battery with new
unstable.
one.
Display is not clear.
※If problem persists, or if you have any questions, please contact
distributor or place of purchase.
※Please note, manufacturer is unable to respond to inquires or provide
service directly. Please contact distributor or place of purchase.
All manuals and user guides at all-guides.com
Model
INSTRUCTION MANUAL
No.
Spindle
LCD Display
Anvil
(Fixed Side)
ON/OFF
Frame
0
SET
【FRONT】
Ratchet Stop
[ON/OFF] Button,
[SET] Button
Insulating
Clamp
Cover
Loosen
【ACCS.】
Calibration Std.
(Not w/ EOM133-25)
Spanner
SR44
FEATURES
Carbide measuring surfaces.
Spherical Anvil Attachment (SR2.5) included.
Auto-display-off function (approx. 6 minutes.)
SR44 (silver oxide battery) included for testing.
Insulating cover・Thermal shield
SAFETY
Always follow the procedures specified below in order to prevent harm
to yourself or others, and to prevent damage to property.
Indicates risk of personal injury or property
CAUTION
damage if not followed.
Always clean measuring surfaces with soft cloth before use.
Do not turn spindle more than 3mm above upper
measurement range.
This is a precision instrument, handle with care. Do not
drop or subject to excessive forces.
Keep away form high voltage and strong magnetic fields.
Instrument damage may result.
Keep instrument away from direct sunlight or high
temperatures such as in a car, or near a stove or heat source.
Do not disassemble or modify.
Please do not use organic solvents to clean the body of
the instrument.
When not being used for long period of time, please
remove battery.
Only us e as directed. Improper use may cause accident or injury.
CAUTION
EOM133- ***
① Rotate the Battery Cover on rear
using coin or similar tool.
② Insert battery with "+" side up.
③ Replace Battery Cover.
When [ON/OFF] Button is pressed, power is turned ON, and
measurement is displayed on the LCD.
Press [ON/OFF] Button a second time to turn power OFF.
Setting the origin used for measurements.
Once set, even when power is off the origin is saved and
Sleeve
does not have to be reset with each use.
Thimble
When battery is replaced origin will go to default setting,
please reset.
5
① Remove any grease or dust from the measuring surfaces
0
45
using a clean cloth, such as a lens cleaning cloth. Make sure
40
no foreign matter is adhered to the measuring surfaces.
② With Spindle Clamp loose, turn until measuring surfaces
touch. Turn until Ratchet Stop clicks 1~3 times.
※ For models other than EOM133-25, please insert the
Lock
supplied Calibration Standard between measuring surfaces.
③ To align the Thimble Scale 0-Point reference lines.
1. Tighten Spindle Clamp to lock Spindle.
2. Insert the spanner into 0-point Adjustment Hole on rear
Spherical (Ball)
of Thimble.
Attachment
3. Use spanner to rotate Sleeve to align the 0-Point lines.
(Silver Oxide Cell)
SR44
④ Press the [SET] Button for more than two seconds.
※ For Test
LCD will display "SET" for 0.5 seconds, and then the
display will read as shown below:
EOM133-25・・・・・ 0.000
Ratchet stop.
EOM133-75・・・・ 50.000
EOM133-125・・ 100.000
The gauge is now ready to take measurements.
① Remove any grease or dust from the measuring surfaces
using a clean cloth, such as lens cleaning cloth. Make sure
PLEASE OBSERVE
no foreign objects are adhered to the measuring surfaces.
② Place object to be measured between the Anvil and Spindle.
③ With the Thimble Clamp loose, turn the Thimble to capture
the measured object between the measuring surfaces.
Stop after 1~3 "Clicks" from the Ratchet Stop.
④ The measured value is displayed on the LCD display.
※ Measurement can also be read off Thimble and Sleeve as
with a standard micrometer.
The Spherical (Ball) Anvil Attachment can be attached
as required.
After mounting, please set 0-Point following the procedure
"Setting the Zero-Point" above.
When the Spherical Attachment is attached, the measurement
indicated on the Sleeve scale will read 5mm larger than
actual size.
If any cutting fluid or moisture gets on the instrument body, wipe
using a soft dry cloth to prevent corrosion.
After use, remove any cutting chips or contamination using a soft
cloth and apply rust preventative oil. Keep out of reach of children.
Only use SR44 type
battery.
Open
Battery
Cover
(Fig. 1)
(Fig. 2)
(Fig. 3)
(Fig. 4)
EOM133-50・・・・ 25.000
● 
EOM133-100・・・ 75.000
EOM133-150・・ 125.000
(Fig. 5)
(Fig. 6)
Make sure the Battery Cover is closed
securely. Please make sure the gasket is
in the proper place on the Battery Cover.
Clamp
Meas. surfaces touch
"Click Click"
5
0
ON/OFF
45
SET
40
Ratchet
Stop
Fig.1
Match origin lines
5
0
ON/OFF
45
SET
40
Thimble
ABS
Fig.2
Rotate until origins match
Spanner
Fig.3
Press for > 2 sec.
5
0
ON/OFF
45
SET
40
Fig. 4
ABS
[SET] Button
Workpiece
"Click Click"
5
0
ON/OFF
0
45
SET
40
Ratchet
Stop
Fig.5
Spherical Attachment
5
0
ON/OFF
0
45
SET
40
Fig.6
Sleeve reading = Meas. + 5mm
Niigata seiki Co., Ltd.
5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522 Fax. : +81-256-33-5518
MAIL intl.sales@niigataseiki.co.jp
URL
http://www.niigataseiki.co.jp

Advertisement

loading

Summary of Contents for Niigata seiki EOM133 Series

  • Page 1 Keep this manual with the instrument if transferred or leased to a third party. ● Setting the origin used for measurements. For inquiries about this product, please contact dealer or Niigata Seiki at the address listed on the following page. Once set, even when power is off the origin is saved and ■PART...
  • Page 2 電 取扱説明書 電池は必ずSR44をお使いく All manuals and user guides at all-guides.com 品番 ご注意 池 電池蓋は確実に閉めてください。 EOM133- *** 開ける ださい。 の パッキンが電池蓋から外れていないこ 入 ①本体裏面の電池蓋を、 矢印の向きに デジタル外側マイ クロメータ とを確認してください。 れ コインなどで回して開けます。 精密外側測定器 方 ②電池を必ず (+) 側を表にしてセット してください。 電池蓋 クランプ 測定面を合わせる カチカチ ③電池蓋を元通りに装着してください。 この度は「デジタル外側マイクロメータ」をお買上げいただきありがとうございます。 この商品はアンビルとスピンドルで測定対象物を挟み、外側長さを測定する精密測定器です。...

This manual is also suitable for:

Eom133-25Eom133-50Eom133-75Eqm133-100Eom133-125Eom133-150