Ventilation unit Temovex Blue 2 / 4
User manual
DESIGN & TECHNICAL INFORMATION
OPERATION & CONTROL
MAINTENANCE & SERVICE
Exhaust air filter, article No: G10125
Supply air filter, article No: G10126
Contains checklist for installation, adjustment, and start-up!
REC Indovent AB, Box 37, 431 21 Mölndal
|
tel.031-675500
|
www.rec-indovent.se
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Temovex Blue 2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for REC Temovex Blue 2

  • Page 1 Ventilation unit Temovex Blue 2 / 4 User manual DESIGN & TECHNICAL INFORMATION OPERATION & CONTROL MAINTENANCE & SERVICE Exhaust air filter, article No: G10125 Supply air filter, article No: G10126 Contains checklist for installation, adjustment, and start-up! REC Indovent AB, Box 37, 431 21 Mölndal tel.031-675500...
  • Page 2: Table Of Contents

    Ventilation unit Temovex Blue 2 / 4 CONTENTS page Options Remote panel – Simple Remote panel – 3-way Checklist Remote panel – with display Quick guide Stove mode Short menu overview Filter change Maintenance & service Cleaning Design & technical information...
  • Page 3: Checklist

    Ventilation unit Temovex Blue 2 / 4 CHECKLIST Checklist installation, adjustment, and start up. ☐ Mounting. The unit is mounted according to the recommendations in this manual, section “installation & adjustment”. ☐ Reheater water. Water pipes supply and return correctly connected. Red tape = supply, blue tape = return.
  • Page 4: Quick Guide

    Alarm history, you can see the latest alarms, but you cannot acknowledge. Load settings is it possible to reload latest saved settings. Unlock functions, you can activate additional functions (contact REC for help). Authorization, you log in for advanced settings, if you are a technician.
  • Page 5: Design & Technical Information

    The unit has low-energy fan of EC type with General description integrated overheating. Temovex BLUE 2 / 4 is an air handling unit 5. Supply air fan (compact cabinet) designed for ventilation of homes, offices, nurseries or other smaller premises.
  • Page 6: Functional Diagram

    Ventilation unit Temovex Blue 2 / 4 Design & Technical information Functional diagram GT11 Control EVBV system Blue KAVK Condensate drain Exhaust air GT11 Temperature sensor, Outdoor air (blue sensor) Cooling coil (option) KAVK Condenstation boiler (option) Electric reheater Bypass damper...
  • Page 7: Technical Specification

    Design & Technical information Ventilation unit Temovex Blue 2 / 4 Teknical specifications (without options where nothing else is stated) Electric heater Water heater Blue 2 Blue 4 Blue 2 Blue 4 Rated electric power (total) 1037 W 1172 W...
  • Page 8: Operation & Control

    OPERATION & CONTROL Ventilation Unit Temovex Blue 2 / 4 General This is a description of the basic functions that you can modify to suit your own preferences and circumstances. The unit’s control system optimizes the function according to the settings you make. As a user of the air handling unit, it is good to know the following: In the menus for heating and cooling, where you as a user have the possibility to make changes, the “auto mode”...
  • Page 9: Menu Guide

    OPERATION & CONTROL Ventilation Unit Temovex Blue 2 / 4 Menu guide On the next page is a table that represents all menus in the program. The table also shows the default setting for each parameter. If the unit, on delivery, deviates from the standard on any parameter, this is marked in the table.
  • Page 10: Menu Table User Parameters

    OPERATION & CONTROL Ventilation Unit Temovex Blue 2 / 4 Menu table user parameters Parameter Default setting Changed setting of this unit 1.1. REC TEMOVEX (Main menu) Mode (Display of current operating mode) Status (Display of status) (Display of current setpoint) Temp.
  • Page 11 OPERATION & CONTROL Ventilation Unit Temovex Blue 2 / 4 (Display of current value) Exhaust air temp. Freeze P. temp. (Display of current value) (Appears if water heater) 1.2.5.1. Room temp. living room (appears if zone control is selected) Actual (Display of current value) (Room temp.
  • Page 12 OPERATION & CONTROL Ventilation Unit Temovex Blue 2 / 4 01-01 - 01-01 __________ 01-01 - 01-01 __________ 01-01 - 01-01 __________ 01-01 - 01-01 __________ 01-01 - 01-01 __________ 01-01 - 01-01 __________ 01-01 - 01-01 __________ 01-01 - 01-01...
  • Page 13: Main Menu

    OPERATION & CONTROL Ventilation Unit Temovex Blue 2 / 4 __________ % (0 – 100 %) ☐Off, ☐Manual Supply air fan Auto ☐Off, ☐Manual __________ % (0 – 100 %) Exhaust air fan Auto __________ % (0 – 100 %) ☐Off, ☐Manual...
  • Page 14: Temperature

    OPERATION & CONTROL Ventilation Unit Temovex Blue 2 / 4 Temperature Temperatures Outdoor temperature is measured on incoming air at the point where the sensor is located. The sensor is placed in the outdoor air duct as far from the unit as possible. The temperature may differ slightly from the actual outside temperature, which may depend on the length of the duct, insulation etc.
  • Page 15: Limit For Cooling

    OPERATION & CONTROL Ventilation Unit Temovex Blue 2 / 4 1.2.5 Zone control This is a more advanced form of room control, where you can have two zones with different temperatures such as one temperature in the bedroom and another in the living room. However, it requires a little extra equipment such as extra heaters and sensors etc.
  • Page 16: Weekend Schedule

    OPERATION & CONTROL Ventilation Unit Temovex Blue 2 / 4 Ú If you have the same times recurring every day in the week you can use the function Monday Friday. If you want the same times on both Saturday, Sunday, and all holidays (specified in the holiday settings), you can Ú...
  • Page 17: Filtertimer

    OPERATION & CONTROL Ventilation Unit Temovex Blue 2 / 4 1.6.1 Filtertimer In this menu, you can set the interval you want between filter changes. The menu also shows how many months remain before the filters should be changed. ATTENTION! This value is only updated once a day. This means that, if "Interval"...
  • Page 18: Options

    OPERATION & CONTROL Ventilation Unit Temovex Blue 2 / 4 Options Remote panel – Simple (art.no. Q100446) Remote panel - Simple (TG-R4) contains a temperature sensor and a set-point knob. The unit is used as a room thermostat, but also allows you to shift the set-point within a certain range.
  • Page 19 OPERATION & CONTROL Ventilation Unit Temovex Blue 2 / 4 Display of actual temperature. Pushing once more (within 10 s) on the menu selection key will turn off the set-point symbol, the indoor temperature symbol will start flashing and the display will show the actual value. The adjustment keys have no function in this case.
  • Page 20: Stove Mode

    OPERATION & CONTROL Ventilation Unit Temovex Blue 2 / 4 Stove mode Extent. The stove mode must be activated from the factory to make the stove mode work. In addition to the software configuration a momentary switch is included in the function (To connect and configure please see the Technician Manual).
  • Page 21: Maintenance & Service

    The filters should not be washed but replaced with · Lift up slightly to release from the hooks. new ones. New filters can be ordered from REC Indovent AB at Unscrew the filter cover www.rec-indovent.se or phone 031-675500. Remove the upper plastic cover incl.
  • Page 22: Checking The Condensate Drain

    MAINTENANCE & SERVICE Ventilation unit Temovex Blue 2 / 4 Checking the condensate drain Service · Service and repairs, beyond normal maintenance, Open and remove the lower door of the unit. · should be carried out by professionals in the...