Klein Tools Lan Explorer VDV526-100 - Cable Tester With Remote Manual

Klein Tools Lan Explorer VDV526-100 - Cable Tester With Remote Manual

Also See for Lan Explorer:

Advertisement

Klein Tools Lan Explorer VDV526-100 - Cable Tester With Remote Manual

FEATURE DETAILS

FEATURE DETAILS

TESTER

  1. RJ45 Shielded Jack
  2. RJ11/RJ12 Shielded Jack
  3. PASS Indicators
  4. Shield Indicator
  5. Test Button
  6. Low Battery Indicator
  7. Power On Indicator
  8. FAULT Indicators
  9. Battery Cover
  10. Screw

REMOTE

  1. Release Latch
  2. RJ45 Shielded Jack
  3. RJ11/RJ12 Shielded Jack

NOTE: No user-serviceable parts.

WIRING CONDITION INDICATORS

PROPERLY WIRED T568A
WIRING CONDITION INDICATORS - Step 1

PROPERLY WIRED T568B
WIRING CONDITION INDICATORS - Step 2
NOTE - RJ11/RJ12 TEST IS FOR STRAIGHT THROUGH WIRING. CROSS OVER WIRING WILL DISPLAY A FAIL RESULT

T568A CABLE WITH SHORT AND OPEN
WIRING CONDITION INDICATORS - Step 3
The 1-2 pair of pins are shorted together and the 7-8 pair is open. The SHORT LED and OPEN LED will illuminate simultaneously.

T568A CABLE WITH A MISWIRE AND UNRECOGNISED CONTINUITY
WIRING CONDITION INDICATORS - Step 4
Pins 1 and 2 on the Near end are connected to Pins 2 and 1 on the Far End.

GENERAL SPECIFICATIONS

The Klein Tools LAN Explorer™ is a portable voice and data cable tester. It tests and troubleshoots RJ45, RJ11 and RJ12 terminated cables and patch cords.

  • Operating Altitude: 6562 ft. (2000 m)
  • Relative Humidity: <90% non-condensing
  • Operating Temperature: 14°F to 122°F (-10°C to 50°C)
  • Storage Temperature: -4°F to 122°F (-20°C to 50°C)
  • Dimensions: 4.9" x 2.5" x 1.3" (12.6 x 6.4 x 3.2 cm)
  • Weight: 5.0 oz. (142 g) including batteries and remote
  • Battery: 9V
  • Maximum non-damaging voltage between pins (RJ Jacks): 66V DC or 55V AC
  • Cable Types: Shielded or Unshielded; Cat7, Cat6/6A, Cat5e, Cat3
  • Maximum Cable Length: 1000 ft. (305 m)
  • Minimum Cable Length (for Split Pair detection): 1.5 ft. (0.5 m)

Specifications subject to change.

KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE


To ensure safe operations, follow these instructions. Failure to observe these warnings can result in fire, electric shock, severe injury or death.

  • Read all safety information before using the product.
  • Carefully read all instructions.
  • The LAN Explorer™ is designed for use on unpowered/dark cable systems.
  • Do not connect the LAN Explorer™ to live AC power.
  • Poorly terminated plugs will damage the jacks on the LAN Explorer. Visually inspect plug before inserting it into the tester.
  • This product is for indoor use only.
  • Turn off the LAN Explorer™ before attempting to replace batteries.
  • Do not open the case, other than the battery compartment.
  • The battery door must be in place and secure before operating product.

  • No user-serviceable parts inside.
  • Do NOT expose to open flame, heat sources, equipment that produces heat, or extremes of environmental temperature.

WARNING SYMBOLS ON TESTER

warning Warning or Caution Wear approved eye protection NOT insulated - will NOT protect against electric shock Read all instructions

WIRING CONDITION INDICATORS

NOTE: See FIG. 1 below for examples of correctly and incorrectly wired connectors.

PASS INDICATORS
Will illuminate if the cable is properly wired. For RJ45, the 4 pairs are wired according to the T568A/568B data cable standards or if cable is wired straight through on RJ11 or RJ12 terminated plugs.

FAULT INDICATORS
MISWIRE: Illuminates if the cable is not wired to one of the cabling standards shown below, or if the conductor wire order on the near end does not match the conductor wire order on the opposite end, i.e. if Pin 1 on near end is wired to Pin 2 on the far end.
OPEN: Illuminates if one or more of the conductor wires on the near end are not terminated properly on the far end, or if any of the near-end contact pins are not properly terminated.
SHORT: Illuminates when two or more conductor wires make contact with each other.

SHIELDED INDICATOR
Illuminates when a shielded (ground wire or foil) data cable is properly connected at both ends, either by ground wire or by foil.

NOTE:

  • When "OPEN" and "MISWIRE" exist simultaneously, only can be judged as "OPEN".
  • When "SHORT" and "MISWIRE" exist simultaneously, only can be judged as"SHORT"
  • When "OPEN" and "SHORT" exist simultaneously for one wire, only can display one status. If "OPEN" first then "SHORT", judge as "OPEN"; If "SHORT" first then "OPEN", judge as "SHORT".
  • If only one fault ("OPEN" or "SHORT") happens to one wire. For example, wire#1 is open, wire#4 and wire#5 are shorted, then both "OPEN" and "SHORT" can be detected and displayed.

NOTE: A Cross-Over Cable, RJ45 or RJ11/12, will flash MISWIRE and PASS simultaneously. On an RJ12-terminated wire with Pin 1 and 6 open faults, "RJ11 PASS" will be the response.

OPERATING INSTRUCTIONS

POWERING ON AND OFF / TESTING A CABLE
The LAN Explorer™ has a single button to start a test. When powered off, a short press of the Test button causes the LAN Explorer™ to turn on, and a cable test to be executed. See INDICATORS section. The results are displayed for 30 seconds before powering off. If another short press occurs before the 30 second time-out, another test cycle will begin, followed by another 30 second time-out.

  1. Connect one end of the cable under test to the RJ45 port (if testing a data cable) or the RJ11/RJ12 port (if testing a voice cable), located at the top of the main tester body.
  2. Connect the other end of the cable under test to the corresponding port on the testing remote.
  3. Press the Test Button to begin the test.

The LAN Explorer™ will automatically power off if there is no test result change for 30 seconds.
To manually power off the LAN Explorer™, press the Test Button for 2 seconds.

MAINTENANCE

BATTERY REPLACEMENT
When the Low Battery indicator blinks or tester does not turn on, the battery must be replaced.

  1. Loosen screw in battery cover to access the battery compartment.
  2. Remove and recycle exhausted battery.
  3. Install new 9V alkaline or carbon zinc battery. Note the proper polarity.
  4. Replace the battery door and fasten it securely with the screw. Do not over-tighten.

CLEANING

Turn tester off and disconnect any cables. Wipe with a clean, dry lint-free cloth.
Do not use abrasive cleaners or solvents.

STORAGE

Remove the battery when the unit is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the General Specifications section, allow the unit to return to normal operating conditions before using.

WARRANTY

www.kleintools.com/warranty

DISPOSAL RECYCLE
Do not place equipment and its accessories in the trash. Items must be properly disposed of in accordance with local regulations.

CUSTOMER SERVICE
KLEIN TOOLS, INC.

450 Bond Street Lincolnshire, IL 60069
1-800-553-4676
customerservice@kleintools.com
www.kleintools.com

Videos

LAN Explorer Data Cable Tester (VDV526-100) Demonstration Video by Klein Tools

LAN Explorer Data Cable Tester (VDV526-100) Review Video by Klein Tools

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Klein Tools Lan Explorer VDV526-100 - Cable Tester With Remote Manual

Advertisement

Need Assistance?

Do you have a question about the Lan Explorer that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents