Download Print this page

Honeywell ADEMCO 5881EN Series Installation And Setup Manual page 2

Rf receiver

Advertisement

HOLES FOR ANTENNAS
AND GROUNDING LUGS
BOARD
SUPPORTING
RECEIVER CIRCUIT BOARD
SLOTS
+
MOUNTING
CLIP
MOUNTING
CLIP
SCREW
GROUNDING
LUG
CABINET
RCVR BRD
+
DETAIL D
ANTENNA AND GROUNDING LUG INSTALLATION
Figure 1: Installing the Receiver Board in the Control's Cabinet
4. Setting the DIP switches (All Receivers):
a. Set the receiver's DIP switch (#2 through #4) to identify the
receiver's address (refer to the DIP switch chart in Figure 3).
b. Verify that DIP switch #1 is in the OFF position.
c. Set DIP switch #5 according to the following chart.
DIP SWITCH #5
For . . .
Commercial Fire Applications
Non-commercial Fire Applications
NOTES:
N
If multiple receivers are used on one control, DIP switch
#5 must be set to the same position on all receivers.
N
DIP switch #5 reduces sensitivity during supervision
message reception. For commercial fire applications, DIP
switch #5 must be in the ON position.
5. Insert the wiring plug (with 4 flying leads) into the
mating socket on the receiver (see Figure 3 for socket
location). Connect the 4 wires to the control's corresponding
keypad
terminals
(see
SPECIFICATIONS section).
6. Install the antennas in the right-hand terminals of the two
terminal blocks at the upper edge of the circuit board, one into
each block's right-hand terminal, and tighten the screws to
secure them.
Caution: Avoid mounting the receiver antennas against a
metal surface.
7. Proceed with any programming of the control that may
be necessary for RF operation, and the installation of the
system's wireless transmitters, as described in the control's
installation and setup guide and the transmitter's installation
instructions.
CABINET
CIRCUIT BOARD
(See Detail D)
+
CONTROL
CIRCUIT
BOARD
(2)
ANTENNA
(2)
(2)
+
ANTENNA
MOUNT
(2 PLACES)
Set to . . .
ON
OFF
"Interface
Wiring"
WWW.DIYALARMFORUM.COM
DETAIL A
SIDE VIEW
OF BOARD
SUPPORTING SLOTS
DETAIL B
SIDE VIEW
OF MOUNTING
CLIP
DETAIL C
SIDE VIEW
OF MOUNTING
CLIP
pcb_RF_mount-V0
NOTES:
N
The receiver can support up to 16 high security (encrypted)
wireless transmitters (keys). The total quantity of wireless
keys (encrypted and unencrypted) that can be used is
determined by the control panel.
N
Wireless key buttons must be enrolled to zones in the control
panel via zone programming first. If the wireless key is to be
used for arming and disarming the VISTA-40 and up, a user
number must then be assigned to the wireless key via user
programming. If it is not done in this order, you will be
unable to respond successfully to the RF button zone number
prompt in user programming.
N
If more than one receiver is being used and you are using
encrypted wireless keys, we recommend that you (a) enter
the GO/NO GO mode, (b) disconnect one receiver, (c) enroll
all encrypted keys into the connected receiver, (d) reconnect
the disconnected receiver, (e) exit the GO/NO GO mode, and
then (f) repeat (a) through (e) for the receiver that was
disconnected.
N
The RED LED located on the receiver's circuit board should
be used as an indicator of strong local radio frequency
in
the
interference. If this LED is continuously illuminated, the
receiver should be relocated.
N
After a successful enrollment of an encrypted key, the
GREEN LED blinks the number of spaces that are free for
additional encrypted key enrollment.
8. Replace the receiver's cover.
2
Figure 2: Tamper Protection
SCREW
5881ENHC-001-V0

Advertisement

loading

This manual is also suitable for:

5881enl5881enm5881enh5881enhc