Download Print this page

3onedata IAC8500-1GC4GT Quick Installation Manual page 3

Industrial wireless controller

Advertisement

Step 4
Click "Login" button to login to the WEB interface of
the device.
Description:
The default IP address of the device is "192.168.3.1".
The default user name and password of the device is
"admin".
If the username or password is lost, user can restore it to
factory settings via device DIP switch or management
software; all modified configurations will be cleared
after restoring to factory settings, so please backup
configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【Specification】
Panel
Gigabit LAN port
10/100/1000
self-adapting RJ45 port, half/full
duplex
MDI/MDI-X self-adaption
Gigabit WAN port
Gigabit
10/100/1000Base-T(X)
1000Base-X SFP
Console Port
USB 2.0 port
USB 3.0 port
Alarm interface
Indicator
Power supply
Input power supply
Access
block
Power consumption
No-load
Full-load
Working
environment
Working temperature
Storage temperature
Working humidity
Protection grade
Base-T(X)
self-adaption
support
Combo,
optional
and
CLI command line management
port (RS-232), RJ45(CLI function
is reserved)
USB Type A female head
USB Type A female head
2-pin 7.62mm pitch terminal block,
support 1 relay alarm output
Power supply indicator, alarm
indicator,
running
indicator,
interface indicator
110~240VAC 50-60Hz
Dual power supply redundancy,
3A over-current protection
terminal
Power supply outlet with switch
3.0W@220VAC
5.0W@220VAC
-40~75℃
-40~85℃
5%~95% (no condensation)
IP30(metal)