However, since the test performed during
normal operation provides more accurate
information on the condition of the exhaust duct
than the installation test, the number of bars
displayed during the two tests may not be the
same.
• Do not interrupt the test cycle, as this could
result in inaccurate results.
• Even if the Flow Sense indicator does not light up
during the test cycle, some restrictions may still
be present in the exhaust system. Refer to the
Venting the Dryer section of this manual for
complete exhaust system and venting
requirements.
Error Codes
Check the error code before you call for service.
When an error occurs, various LEDs will light up
and a chime will sound.
LED
Possible Cause & Solution
light
Low or
Temperature sensor failure.
Mediu
• Turn off the appliance and call for
m
service.
Energy
Humidity sensor failure.
Saver
• Turn off the appliance and call for
service.
High,
Electric dryer power cord is not
Damp
connected correctly, or house power
or
supply is incorrect.
Normal
• Reset circuit breaker or replace
fuse. Do not increase the fuse
capacity.
House fuse is blown, circuit breaker
has tripped, or power outage has
occurred.
• If the problem is a circuit overload,
have it corrected by a qualified
electrician.
Very
Gas supply or service turned off. (Gas
Model only.)
• Confirm that house gas shutoff and
the dryer gas shutoff are both fully
open.
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed
transition duct
Check for blockages and lint buildup.
Make sure the ductwork is not crushed or
restricted.
INSTALLATION
25
Too many elbows or
exhaust too long