  • Page 1 SF-SA-140 -B.qxd 16/05/2005 11:19 Page 1 PIR Motion Detector E-700 IQ Europe Limited Sandbeck Lane, Wetherby LS22 7TW. Visit us at www.iq-europe.co.uk V2.0 - 02/05 Installation helpline 0871 717 1100 IQ-140-B...
  • Page 2 SF-SA-140 -B.qxd 16/05/2005 11:19 Page 2 MANUFACTURER'S EXTENDED WARRANTY In addition to your statutory rights relating to this product it is also guaranteed by IQ (Europe) Limited ("IQ") for 12 months from the date of purchase against faulty materials or workmanship which affect its designed ability to detect or switch.
  • Page 3: General Information

    SF-SA-140 -B.qxd 16/05/2005 11:19 Page 3 SECTION ONE GENERAL INFORMATION The unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the attached lighting load will illuminate for a user-determined time period. An integral daylight sensor ensures night-only operation. PARTS INCLUDED - PIR Sensor unit.
  • Page 4: Installation

    SF-SA-140 -B.qxd 16/05/2005 11:19 Page 4 SECTION THREE INSTALLATION After choosing a suitable location (see previous section) install the unit as follows: The unit is suitable for connection to a 240 V ac 50Hz electricity supply. It is suggested that 3-core round flexible cable of 1mm²...
  • Page 5: Top View

    SF-SA-140 -B.qxd 16/05/2005 11:19 Page 5 TOP VIEW 140º Dusk Time SIDE VIEW 2.5m Lens Mask Less sensitive Restrict long detection Restrict short detection More Restrict RHS detection Restrict LHS detection sensitive...
  • Page 6: Operation And Testing

    SF-SA-140 -B.qxd 16/05/2005 11:19 Page 6 SECTION FOUR OPERATION AND TESTING WALK TESTING PROCEDURE The sensor will rotate from left to right, and tilt forward or backward. Adjust the sensor to point in the desired direction. Set the two adjustment controls on the underside of the unit (diagram C) to the following positions: TIME - Fully anti-clockwise DUSK - Fully clockwise...
  • Page 7: Technical Specifications

    If problems still exist, do not immediately return the unit to store. Telephone the IQ Customer Helpline 0871 71 71 100 Weekdays 9.00am - 5.00pm support@iq-group.com www.iq-europe.co.uk Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query.
  • Page 8: Troubleshooting Guide

    SF-SA-140 -B.qxd 16/05/2005 11:19 Page 8 SECTION SIX TROUBLESHOOTING GUIDE PROBLEM SOLUTION o Lamp stays ON all the time at Cover PIR lens with a thick cloth. If the light turns out, check night. detection area for heat or reflective source. If the light stays on, check wiring.
  • Page 9 SF-SA-140 -B.qxd 16/05/2005 11:19 Page 9 DID YOU KNOW... IQ products are designed and manufactured to give many years of trouble-free service. The materials used during manufacture have been selected to allow the product to be easily recycled when no longer functional. Waste electrical products should not be disposed of with household waste.