AEG PROSTEAM 7000 LF7E7431BI User Manual page 40

Table of Contents

Advertisement

40
www.aeg.com
13.9 Cleaning the drain pump
WARNING!
Disconnect the mains plug
from the mains socket.
Regularly check the drain
pump filter and make sure
that it is clean.
Proceed as follows to clean the pump:
1
2
Clean the drain pump if:
• The appliance does not drain the
water.
• The drum does not turn.
• The appliance makes an unusual
noise because of the blockage of the
drain pump.
• The display shows the alarm code
.
WARNING!
• Do not remove the filter
while the appliance
operates.
• Do not clean the pump if
the water in the appliance
is hot. Wait until the water
cools down
1. Open the pump cover.
2. Place a suitable bowl below the drain pump
access to collect the water that flows out.
Always keep a rag nearby to dry up any water
spillages when removing the filter.

Hide quick links: