Safety Devices - Fujitsu AUXG07-18KVLA Design & Technical Manual

Air conditioner 3-unit multi-split type
Hide thumbs Also See for AUXG07-18KVLA:
Table of Contents

Advertisement

10. Safety devices

Indoor unit
Model name
type
AUXG07KVLA
AUXG09KVLA
Compact
AUXG12KVLA
cassette
AUXG14KVLA
AUXG18KVLA
ARXG07KSLAP
ARXG09KSLAP
Mini duct
ARXG12KSLAP
ARXG14KSLAP
ARXG18KSLAP
ARXG07KLLAP
ARXG09KLLAP
ARXG12KLLAP
ARXG14KLLAP
Slim duct
ARXG18KLLAP
ASYG07KGTB
ASYG09KGTB
ASYG12KGTB
ASYG14KGTB
ASYG07KGTE
ASYG09KGTE
ASYG12KGTE
Wall mounted
ASYG14KGTE
ASYG18KMTB
ASYG18KMTE
ASYG07KMTB
ASYG09KMTB
ASYG12KMTB
ASYG14KMTB
PCB* fuse
Fan motor thermal protector
Activate: 100 ±15°C
Fan motor stop
Reset: 95 ±10°C
Fan motor restart
Activate: 135 ±15°C
Fan motor stop
250 V, 5 A
Reset: 105 ±15°C
Fan motor restart
Activate: 135 ±15°C
Fan motor stop
Reset: 115 ±15°C
Fan motor restart
Activate: 110 ±15°C
Fan motor speed down
Reset: 110 ±15°C
Fan motor speed recover
Activate: 125 ±10°C
Fan motor stop
Reset: 100 ±10°C
Fan motor restart
Activate: 110 ±15°C
Fan motor speed down
Reset: 110 ±15°C
Fan motor speed recover
Activate: 125 ±10°C
Fan motor stop
250 V, 3.15 A
Reset: 100 ±10°C
Fan motor restart
Activate: 125 ±24°C
Fan motor stop
Reset: 100 ±25°C
Fan motor restart
Activate: More than 95 °C
Fan motor speed down
Reset: 95 °C or less
Fan motor speed recover
Activate: 125 ±10 °C
Fan motor stop
Reset: 100 ±10 °C
Fan motor restart
- 147 -
Terminal
Float
thermal
switch
fuse
102°C Off
10. Safety devices

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents