Mitsubishi Electric MUZ-LN35VGHZ Service Manual page 48

Hide thumbs Also See for MUZ-LN35VGHZ:
Table of Contents

Advertisement

H Check of R.V. coil
MUZ-LN25/35VGHZ MUZ-LN25/35VGHZ2
First of all, measure the resistance of R.V. coil to check if the coil is defective. Refer to 12-4.
In case CN721 is disconnected or R.V. coil is open, voltage is generated between the terminal pins of the connector
although no signal is being transmitted to R.V. coil.
Check if CN721 is connected.
Unit operates in COOL mode even if it is set to HEAT mode.
Disconnect connector between the
compressor and the IGBT module
(IC700).
Turn ON the power supply and press
EMERGENCY OPERATION switch
twice (HEAT mode).
Unit operates in HEAT mode even if it is set to COOL mode.
Disconnect connector between the
compressor and the IGBT module
(IC700).
Turn ON the power supply and
press EMERGENCY OPERATION
switch once (COOL mode).
MUZ-LN50VGHZ
First of all, measure the resistance of R.V. coil to check if the coil is defective. Refer to 12-4.
In case CN602 is disconnected or R.V. coil is open, voltage is generated between the terminal pins of the connector
although no signal is being transmitted to R.V. coil.
Check if CN602 is connected.
Unit operates in COOL mode even if it is set to HEAT mode.
Disconnect connector between the
compressor and the power module
(IC700).
Turn ON the power supply and press
EMERGENCY OPERATION switch
twice (HEAT mode).
Unit operates in HEAT mode even if it is set to COOL mode.
Disconnect connector between the
compressor and the power module
(IC700).
Turn ON the power supply and
press EMERGENCY OPERATION
switch once (COOL mode).
OBH768B
Is there 230VAC between CN721
on the inverter P.C. board 3 minutes
after the power supply is turned ON?
Yes
Replace the 4-way valve.
Is there 230VAC between CN721
on the inverter P.C. board 3 minutes
after the power supply is turned ON?
No
Replace the 4-way valve.
Is there 230VAC between CN602
on the inverter P.C. board 3 minutes
after the power supply is turned ON?
Yes
Replace the 4-way valve.
Is there 230VAC between CN602
on the inverter P.C. board 3 minutes
after the power supply is turned ON?
No
Replace the 4-way valve.
48
and
Replace the inverter
No
P.C. board.
and
Replace the inverter
Yes
P.C. board.
and
Replace the inverter
No
P.C. board.
and
Replace the inverter
Yes
P.C. board.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Muz-ln25vghzMuz-ln50vghzMuz-ln25vghz2Muz-ln35vghz2