Refrigerant System Diagram - Mitsubishi Electric MUZ-LN35VGHZ Service Manual

Hide thumbs Also See for MUZ-LN35VGHZ:
Table of Contents

Advertisement

8

REFRIGERANT SYSTEM DIAGRAM

MUZ-LN25VGHZ
MUZ-LN25VGHZ2 MUZ-LN35VGHZ2
Refrigerant pipe ø9.52
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø6.35
(with heat insulator)
MUZ-LN50VGHZ
Refrigerant pipe ø 9.52
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø 6.35
(with heat insulator)
OBH768B
MUZ-LN35VGHZ
Muffler
Stop valve
Stop valve
Capillary tube
(with strainer)
ø4.0×ø2.4×240
Strainer
#100
4-way valve
Stop valve
Capillary tube
Strainer
ø 4.0 ×ø 2.4 × 100
#100
Stop valve
4-way valve
Muffler
Discharge
temperature
thermistor
RT62
Compressor
Defrost
thermistor
RT61
LEV
Discharge
temperature
thermistor
Defrost
RT62
thermistor
RT61
Compressor
LEV
Strainer
#100
Muffler
16
Outdoor heat
exchanger
temperature
thermistor
Outdoor
RT68
heat
exchanger
Ambient
temperature
thermistor
RT65
Strainer
#100
R.V. coil
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
Outdoor
heat
Ambient
exchanger
temperature
thermistor
RT65
Outdoor heat
exchanger
temperature
thermistor
RT68
R.V. coil
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
Unit: mm

Hide quick links: